Evidence map›Paper›PMID 34649582›Full record

ArticleJournal of orthopaedic surgery and research2021

The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis.

Yin Shi, Yi-Zhou Xie, Qun Zhou, Yang Yu, Xiao-Hong Fan

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yin ShiHospital of Chengdu University of Traditional Chinese Medicine, No. 39 Shi-er-qiao Road, Chengdu, 610072, Sichuan Province, People's Republic of China.
Yi-Zhou XieHospital of Chengdu University of Traditional Chinese Medicine, No. 39 Shi-er-qiao Road, Chengdu, 610072, Sichuan Province, People's Republic of China.
Qun ZhouChengdu University of Traditional Chinese Medicine, No. 1166 Liu-tai Avenue, Chengdu, 611137, Sichuan Province, People's Republic of China.
Yang YuHospital of Chengdu University of Traditional Chinese Medicine, No. 39 Shi-er-qiao Road, Chengdu, 610072, Sichuan Province, People's Republic of China.
Xiao-Hong FanHospital of Chengdu University of Traditional Chinese Medicine, No. 39 Shi-er-qiao Road, Chengdu, 610072, Sichuan Province, People's Republic of China. fxh202010@163.com.

Funding

health commission of sichuan province S17024
6 · The paper itself

Abstract

objectiveTo evaluate the biomechanical influence after percutaneous endoscopic lumbar facetectomy in different diameters on segmental range of motion (ROM) and intradiscal pressure (IDP) of the relevant segments by establishing three dimensional finite element (FE) model.

methodsAn intact L3-5 model was successfully constructed from the CT of a healthy volunteer as Model A (MA). The Model B (MB), Model C (MC) and Model D (MD) were obtained through facetectomy on L4 inferior facet in diameters 7.5 mm, 10 mm and 15 mm on MA for simulation. The ROM and IDP of L3/4 and L4/5 of four models were all compared in forward flexion, backward extension, left and right bending, left and right rotation.

resultsCompared with MA, the ROM of L4/5 of MB, MC and MD all increased. MD changed more significantly than MB and MC in backward extension, right bending and right rotation. But that of MB and MC on L3/4 had no prominent change, while MD had a slight increase in backward extension. The IDP of MB and MC on L4/5 in six states was similar to MA, yet MD increased obviously in backward extension, right bending, left and right rotation. The IDP on L3/4 of MB and MC was resemble to MA in six conditions, nevertheless MD increased slightly only in backward extension.

conclusionCompared with the facetectomy in diameters 7.5 mm and 10 mm, the mechanical effect brought by facetectomy in diameter 15 mm on the operating segment changed more significantly, and had a corresponding effect on the adjacent segments.

Indexed as

Spinal FusionBiomechanical PhenomenaEndoscopesFinite Element AnalysisHumansLumbar VertebraeRange of Motion, ArticularBiomechanical effectFacetectomyPosterior lumbar percutaneous endoscopyThree-dimensional finite element analysis

Identifiers

PMID34649582
PMCPMC8515756

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.