Can a low-cost exercise monitor provide useful heart rate monitoring for use in low-resource emergency departments?

Thomas A O'Mara, Miguel Armengol de la Hoz, Oren J Mechanic, Alon Dagan

Open access · diamondAbstract read
In one paragraph

Article in Clinical and experimental emergency medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.1field-weighted citation impact, top 61% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Thomas A O'MaraDepartment of Emergency Medicine, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Miguel Armengol de la HozCardiovascular Research Center, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Oren J MechanicHarvard Medical Faculty Physicians at BIDMC, Boston, MA, USA.
Alon DaganMIT Critical Data, Laboratory for Computational Physiology, Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA.
Beth Israel Deaconess Medical Center · USHarvard University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveOur objective was to study the clinical monitoring capabilities of a low-cost fitness wristband while measuring patient satisfaction with a mobility permitting device in the emergency department.

methodsPatients enrolled were on continuous three-lead telemetry monitoring in a high acuity zone of the emergency department. Patients were given a fitness band to wear while simultaneously monitored with standard three-lead monitor. A brief survey was conducted upon study end, and data was compared between wristband and three-lead telemetry. Median heart rate (HR) values were calculated, a Bland-Altman plot was generated, and sensitivity and specificity were calculated for comparison of the formal telemetry and the inexpensive wristband.

resultsThirty-four patients with an average age of 61.5 years were enrolled. From June to October 2019, over 100 hours of data were collected. In comparison for comfort, participants scored 9.5 of 10, preferring wristband over telemetry. Using a correlation coefficient graph, we found a significant disparity of HR readings within a telemetry range of 40 to 140 beats/min. An R-value of 0.36 was detected. Using a Bland-Altman plot, we observed a significant difference in HR between the telemetry monitor and the wristband. The sensitivity and specificity of the wristband to detect bradycardia (HR <60 beats/min) were 76% and 86%, respectively, while the sensitivity and specificity of the wristband to detect tachycardia (HR >100 beats/min) were 92% and 51%, respectively.

conclusionInexpensive fitness bands cannot be a suitable tool for monitoring patient's HR because of inaccuracy in detecting bradycardia or tachycardia.

Indexed as

Fitness trackersGlobal healthInternet of thingsMonitoring, physiologicTelemedicine

Identifiers

PMID34649408
PMCPMC8517460
OpenAlexW3202403100

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.