ArticleApplied spectroscopy2022

On the Limit of Detection in Infrared Spectroscopic Imaging.

Laurin Lux, Yamuna Phal, Pei-Hsuan Hsieh, Rohit Bhargava

Open access · greenAbstract read
In one paragraph

Article in Applied spectroscopy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Amino-Termination of Silicon Carbide Nanoparticles.Nanomaterials (Basel, Switzerland) · 2023
    Article
  7. Resolution Limit in Infrared Chemical Imaging.The journal of physical chemistry. C, Nanomaterials and interfaces · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Laurin LuxBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
Yamuna PhalBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
Pei-Hsuan HsiehBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA.
Rohit BhargavaBeckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA.ORCID https://orcid.org/0000-0001-7360-994X
University of Illinois Urbana-Champaign · US

Funding

Discrete Frequency Infrared Spectroscopic Imaging for Breast HistopathologyR01EB009745 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BHARGAVA, ROHIT · 2010 to 2025
$5.1M
Real time colon histopathology by infrared spectroscopic imagingR01CA260830 · NCI · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BHARGAVA, ROHIT · 2021 to 2025
$2.3M
Instrument development for vibrational circular dichroism imagingR01GM142172 · NIGMS · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BHARGAVA, ROHIT · 2021 to 2024
$1.6M
NCI NIH HHS R01 CA260830NIBIB NIH HHS R01 EB009745NIGMS NIH HHS R01 GM142172
6 · The paper itself

Abstract

Infrared (IR) spectroscopic imaging instruments' performance can be characterized and optimized by an analysis of their limit of detection (LOD). Here we report a systematic analysis of the LOD for Fourier transform IR (FT-IR) and discrete frequency IR (DFIR) imaging spectrometers. In addition to traditional measurements of sample and blank data, we propose a decision theory perspective to pose the determination of LOD as a binary classification problem under different assumptions of noise uniformity and correlation. We also examine three spectral analysis approaches, namely, absorbance at a single frequency, average of absorbance over selected frequencies and total spectral distance - to suit instruments that acquire discrete or contiguous spectral bandwidths. The analysis is validated by refining the fabrication of a bovine serum albumin protein microarray to provide eight uniform spots from ∼2.8 nL of solution for each concentration over a wide range (0.05-10 mg/mL). Using scanning parameters that are typical for each instrument, we estimate a LOD of 0.16 mg/mL and 0.12 mg/mL for widefield and line scanning FT-IR imaging systems, respectively, using the spectral distance approach, and 0.22 mg/mL and 0.15 mg/mL using an optimal set of discrete frequencies. As expected, averaging and the use of post-processing techniques such as minimum noise fraction transformation results in LODs as low as ∼0.075 mg/mL that correspond to a spotted protein mass of ∼112 fg/pixel. We emphasize that these measurements were conducted at typical imaging parameters for each instrument and can be improved using the usual trading rules of IR spectroscopy. This systematic analysis and methodology for determining the LOD can allow for quantitative measures of confidence in imaging an analyte's concentration and a basis for further improving IR imaging technology.

Indexed as

ProteinsFourier AnalysisLimit of DetectionSpectrophotometry, InfraredSpectroscopy, Fourier Transform InfraredProteinsbinary hypothesis testingchemical imagingdiscrete frequency infraredFourier transform-infrared spectroscopyFT-IRLimit of detectionLODnoise

Identifiers

PMID34643135
PMCPMC10539114
OpenAlexW3205969437

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.