Evidence map›Paper›PMID 34641151›Full record

ArticlePolymers2021

Capacitive and Conductometric Type Dual-Mode Relative Humidity Sensor Based on 5,10,15,20-tetra Phenyl Porphyrinato Nickel (II) (TPPNi).

Rizwan Akram, Muhammad Yaseen, Zahid Farooq, Ayesha Rauf, Ziyad M Almohaimeed, Muhammad Ikram, Qayyum Zafar

Abstract read
In one paragraph

Article in Polymers, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rizwan AkramDepartment of Electrical Engineering, College of Engineering, Qassim University, P.O. Box 6677, Buraydah 51452, Saudi Arabia.ORCID 0000-0003-0910-9304
Muhammad YaseenDepartment of Chemistry, Division of Science & Technology, University of Education Lahore, Lahore 54000, Pakistan.
Zahid FarooqDepartment of Physics, Division of Science & Technology, University of Education Lahore, Lahore 54000, Pakistan.
Ayesha RaufDepartment of Physics, University of Management and Technology, Lahore 54000, Pakistan.
Ziyad M AlmohaimeedDepartment of Electrical Engineering, College of Engineering, Qassim University, P.O. Box 6677, Buraydah 51452, Saudi Arabia.
Muhammad IkramSolar Cell Applications Research Lab., Department of Physics, Government College University, Lahore 54000, Pakistan.ORCID 0000-0001-7741-789X
Qayyum ZafarDepartment of Physics, University of Management and Technology, Lahore 54000, Pakistan.ORCID 0000-0001-6763-9587

Funding

Qassim University 10233-QEC-2020-1-3-I
6 · The paper itself

Abstract

(1) Background: A quest for a highly sensitive and reliable humidity monitoring system for a diverse variety of applications is quite vital. Specifically, the ever-increasing demand of humidity sensors in applications ranging from agriculture to healthcare equipment (to cater the current demand of COVID-19 ventilation systems), calls for a selection of suitable humidity sensing material. (2) Methods: In the present study, the TPPNi macromolecule has been synthesized by using a microwave-assisted synthesis process. The layer structure of the fabricated humidity sensor (Al/TPPNi/Al) consists of pair of planar 120 nm thin aluminum (Al) electrodes (deposited by thermal evaporation) and ~160 nm facile spin-coated solution-processable organic TPPNi as an active layer between the ~40 µm electrode gap. (3) Results: Electrical properties (capacitance and impedance) of sensors were found to be substantially sensitive not only on relative humidity but also on the frequency of the input bias signal. The proposed sensor exhibits multimode (capacitive and conductometric) operation with significantly higher sensitivity ~146.17 pF/%RH at 500 Hz and 48.23 kΩ/%RH at 1 kHz. (4) Conclusions: The developed Al/TPPNi/Al surface type humidity sensor's much-improved detecting properties along with reasonable dynamic range and response time suggest that it could be effective for continuous humidity monitoring in multi environmental applications.

Indexed as

capacitive and conductometric sensorGrothus mechanismhumidity sensingporous surface morphologyresponse and recovery time