Evidence map›Paper›PMID 34641013›Full record

ArticleSensors (Basel, Switzerland)2021

A Novel Capacitive Measurement Device for Longitudinal Monitoring of Bone Fracture Healing.

Angela Sorriento, Marcello Chiurazzi, Luca Fabbri, Michelangelo Scaglione, Paolo Dario, Gastone Ciuti

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. The application of impantable sensors in the musculoskeletal system: a review.Frontiers in bioengineering and biotechnology · 2024
    Review
  4. Article
  5. Sensors and digital medicine in orthopaedic surgery.OTA international : the open access journal of orthopaedic trauma · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Angela SorrientoThe BioRobotics Institute, Scuola Superiore Sant'Anna, 56025 Pisa, Italy.ORCID 0000-0001-5891-4508
Marcello ChiurazziThe BioRobotics Institute, Scuola Superiore Sant'Anna, 56025 Pisa, Italy.ORCID 0000-0002-7056-8844
Luca FabbriOrthopaedic and Traumatology Department, Pisa University Hospital, 56126 Pisa, Italy.
Michelangelo ScaglioneOrthopaedic and Traumatology Department, Pisa University Hospital, 56126 Pisa, Italy.
Paolo DarioThe BioRobotics Institute, Scuola Superiore Sant'Anna, 56025 Pisa, Italy.
Gastone CiutiThe BioRobotics Institute, Scuola Superiore Sant'Anna, 56025 Pisa, Italy.ORCID 0000-0002-0855-7976

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The healing process of surgically-stabilised long bone fractures depends on two main factors: (a) the assessment of implant stability, and (b) the knowledge of bone callus stiffness. Currently, X-rays are the main diagnostic tool used for the assessment of bone fractures. However, they are considered unsafe, and the interpretation of the clinical results is highly subjective, depending on the clinician's experience. Hence, there is the need for objective, non-invasive and repeatable methods to allow a longitudinal assessment of implant stability and bone callus stiffness. In this work, we propose a compact and scalable system, based on capacitive sensor technology, able to measure, quantitatively, the relative pins displacements in bone fractures treated with external fixators. The measurement device proved to be easily integrable with the external fixator pins. Smart arrangements of the sensor units were exploited to discriminate relative movements of the external pins in the 3D space with a resolution of 0.5 mm and 0.5°. The proposed capacitive technology was able to detect all of the expected movements of the external pins in the 3D space, providing information on implant stability and bone callus stiffness.

Indexed as

Fracture HealingFractures, BoneExternal FixatorsHumansRadiographybiomechanicsbone fracture healingcapacitive-based sensorexternal fixatorslongitudinal monitoringmeasurement device

Identifiers

PMID34641013
PMCPMC8512850

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.