Evidence map›Paper›PMID 34640929›Full record

ArticleSensors (Basel, Switzerland)2021

A High-Speed Demodulation Technology of Fiber Optic Extrinsic Fabry-Perot Interferometric Sensor Based on Coarse Spectrum.

Peng Zhang, Ying Wang, Yuru Chen, Xiaohua Lei, Yi Qi, Jianghua Feng, Xianming Liu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Peng ZhangKey Lab of Optoelectronic Technology and Systems Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China.
Ying WangKey Lab of Optoelectronic Technology and Systems Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China.
Yuru ChenKey Lab of Optoelectronic Technology and Systems Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China.
Xiaohua LeiKey Lab of Optoelectronic Technology and Systems Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China.
Yi QiKey Lab of Optoelectronic Technology and Systems Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China.
Jianghua FengKey Lab of Optoelectronic Technology and Systems Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China.
Xianming LiuKey Lab of Optoelectronic Technology and Systems Ministry of Education, College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China.

Funding

Fundamental Research Funds for the Central Universities 2020CDJ-LHZZ-071General projects of Chongqing Natural Science Foundation cstc2020jcyj-msxmX0948National Natural Science Foundation of China 51675068National Natural Science Foundation of China 51975077National Natural Science Foundation of China 52175530National Natural Science Foundation of China 61875023
6 · The paper itself

Abstract

A fast real-time demodulation method based on the coarsely sampled spectrum is proposed for transient signals of fiber optic extrinsic Fabry-Perot interferometers (EFPI) sensors. The feasibility of phase demodulation using a coarse spectrum is theoretically analyzed. Based on the coarse spectrum, fast Fourier transform (FFT) algorithm is used to roughly estimate the cavity length. According to the rough estimation, the maximum likelihood estimation (MLE) algorithm is applied to calculate the cavity length accurately. The dense wavelength division multiplexer (DWDM) is used to split the broadband spectrum into the coarse spectrum, and the high-speed synchronous ADC collects the spectrum. The experimental results show that the system can achieve a real-time dynamic demodulation speed of 50 kHz, a static measurement root mean square error (RMSE) of 0.184 nm, and a maximum absolute and relative error distribution of 15 nm and 0.005% of the measurement cavity length compared with optical spectrum analyzers (OSA).

Indexed as

coarse spectrumextrinsic Fabry-Perot interferometershigh-speed demodulationmaximum likelihood estimation

Identifiers

PMID34640929
PMCPMC8512430

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.