Evidence map›Paper›PMID 34640681›Full record

ArticleSensors (Basel, Switzerland)2021

Automated Detection and Removal of Cardiac and Pulse Interferences from Neonatal EEG Signals.

Gabriella Tamburro, Pierpaolo Croce, Filippo Zappasodi, Silvia Comani

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Gabriella TamburroBehavioral Imaging and Neural Dynamics Center, G. d'Annunzio University of Chieti-Pescara, 66100 Chieti, Italy.
Pierpaolo CroceDepartment of Neuroscience, Imaging and Clinical Sciences, G. d'Annunzio University of Chieti-Pescara, 66100 Chieti, Italy.ORCID 0000-0001-7279-3052
Filippo ZappasodiDepartment of Neuroscience, Imaging and Clinical Sciences, G. d'Annunzio University of Chieti-Pescara, 66100 Chieti, Italy.
Silvia ComaniBehavioral Imaging and Neural Dynamics Center, G. d'Annunzio University of Chieti-Pescara, 66100 Chieti, Italy.ORCID 0000-0001-8100-457X
University of Chieti-Pescara · IT

Funding

European Commission 813483
6 · The paper itself

Abstract

Electrical cardiac and pulsatile interference is very difficult to remove from electroencephalographic (EEG) signals, especially if recorded in neonates, for which a small number of EEG channels is used. Several methods were proposed, including Blind Source Separation (BSS) methods that required the use of artificial cardiac-related signals to improve the separation of artefactual components. To optimize the separation of cardiac-related artefactual components, we propose a method based on Independent Component Analysis (ICA) that exploits specific features of the real electrocardiographic (ECG) signals that were simultaneously recorded with the neonatal EEG. A total of forty EEG segments from 19-channel neonatal EEG recordings with and without seizures were used to test and validate the performance of our method. We observed a significant reduction in the number of independent components (ICs) containing cardiac-related interferences, with a consequent improvement in the automated classification of the separated ICs. The comparison with the expert labeling of the ICs separately containing electrical cardiac and pulsatile interference led to an accuracy = 0.99, a false omission rate = 0.01 and a sensitivity = 0.93, outperforming existing methods. Furthermore, we verified that true brain activity was preserved in neonatal EEG signals reconstructed after the removal of artefactual ICs, demonstrating the effectiveness of our method and its safe applicability in a clinical context.

Indexed as

AlgorithmsArtifactsElectroencephalographyHeart RateHumansInfant, NewbornSeizuresautomated artefact removalblind source separation methods (BSS)cardiac interferenceelectrocardiography (ECG)independent component analysis (ICA)neonatal electroencephalography (EEG)pulse interference

Identifiers

PMID34640681
PMCPMC8512476
OpenAlexW3201504893

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.