Evidence map›Paper›PMID 34637140›Full record

SynthesisThe Cochrane database of systematic reviews2021

Ultrasound guidance for arterial (other than femoral) catheterisation in adults.

Ronald Lg Flumignan, Virginia Fm Trevisani, Renato D Lopes, Jose Cc Baptista-Silva, Carolina Dq Flumignan, Luis Cu Nakano

Open access · greenAbstract readSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 3 pooled it
1.3field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 3 syntheses or guidelines pooled it, 21 citations in OpenAlex.

  1. Duplex ultrasound for surveillance of lower limb revascularisation.The Cochrane database of systematic reviews · 2023
    Pooled it
  2. Ultrasound-guided arterial cannulation in the paediatric population.The Cochrane database of systematic reviews · 2023
    Pooled it
  3. Pooled it
  4. Trial
  5. Article
  6. Review
  7. Review
  8. Review
  9. Article
  10. Article
  11. Ultrasound-guided Arterial Cannulation: What are We Missing and Where are We Headed?Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2024
    Article
  12. Acoustic Shadowing to Facilitate Ultrasound Guided Arterial Cannulation: A Systematic Review and Meta-analysis of Randomized Controlled Trials.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2024
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Ronald Lg FlumignanDepartment of Surgery, Division of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, São Paulo, Brazil.
Virginia Fm TrevisaniEmergency Medicine, Universidade Federal de São Paulo, São Paulo, Brazil.
Renato D LopesDivision of Cardiology, Duke University Medical Center, Durham, USA.
Jose Cc Baptista-SilvaDepartment of Surgery, Division of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, São Paulo, Brazil.
Carolina Dq FlumignanDepartment of Surgery, Division of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, São Paulo, Brazil.
Luis Cu NakanoDepartment of Surgery, Division of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, São Paulo, Brazil.
Universidade Federal de São Paulo · BRDuke Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundArterial vascular access is a frequently performed procedure, with a high possibility for adverse events (e.g. pneumothorax, haemothorax, haematoma, amputation, death), and additional techniques such as ultrasound may be useful for improving outcomes. However, ultrasound guidance for arterial access in adults is still under debate.

objectivesTo assess the effects of ultrasound guidance for arterial (other than femoral) catheterisation in adults. SEARCH

methodsWe searched CENTRAL, MEDLINE, Embase, LILACS, and CINAHL on 21 May 2021. We also searched IBECS, WHO ICTRP, and ClinicalTrials.gov on 16 June 2021, and we checked the reference lists of retrieved articles. SELECTION CRITERIA: Randomised controlled trials (RCTs), including cross-over trials and cluster-RCTs, comparing ultrasound guidance, alone or associated with other forms of guidance, versus other interventions or palpation and landmarks for arterial (other than femoral) guidance in adults. DATA COLLECTION AND ANALYSIS: Two review authors independently performed study selection, extracted data, assessed risk of bias, and assessed the certainty of evidence using GRADE. MAIN

resultsWe included 48 studies (7997 participants) that tested palpation and landmarks, Doppler auditory ultrasound assistance (DUA), direct ultrasound guidance with B-mode, or any other modified ultrasound technique for arterial (axillary, dorsalis pedis, and radial) catheterisation in adults. Radial artery Real-time B-mode ultrasound versus palpation and landmarks Real-time B-mode ultrasound guidance may improve first attempt success rate (risk ratio (RR) 1.44, 95% confidence interval (CI) 1.29 to 1.61; 4708 participants, 27 studies; low-certainty evidence) and overall success rate (RR 1.11, 95% CI 1.06 to 1.16; 4955 participants, 28 studies; low-certainty evidence), and may decrease time needed for a successful procedure (mean difference (MD) -0.33 minutes, 95% CI -0.54 to -0.13; 4902 participants, 26 studies; low-certainty evidence) up to one hour compared to palpation and landmarks. Real-time B-mode ultrasound guidance probably decreases major haematomas (RR 0.35, 95% CI 0.23 to 0.56; 2504 participants, 16 studies; moderate-certainty evidence). It is uncertain whether real-time B-mode ultrasound guidance has any effect on pseudoaneurysm, pain, and quality of life (QoL) compared to palpation and landmarks (very low-certainty evidence). Real-time B-mode ultrasound versus DUA One study (493 participants) showed that real-time B-mode ultrasound guidance probably improves first attempt success rate (RR 1.35, 95% CI 1.11 to 1.64; moderate-certainty evidence) and time needed for a successful procedure (MD -1.57 minutes, 95% CI -1.78 to -1.36; moderate-certainty evidence) up to 72 hours compared to DUA. Real-time B-mode ultrasound guidance may improve overall success rate (RR 1.13, 95% CI 0.99 to 1.29; low-certainty evidence) up to 72 hours compared to DUA. Pseudoaneurysm, major haematomas, pain, and QoL were not reported. Real-time B-mode ultrasound versus modified real-time B-mode ultrasound Real-time B-mode ultrasound guidance may decrease first attempt success rate (RR 0.68, 95% CI 0.55 to 0.84; 153 participants, 2 studies; low-certainty evidence), may decrease overall success rate (RR 0.93, 95% CI 0.86 to 1.01; 153 participants, 2 studies; low-certainty evidence), and may lead to no difference in time needed for a successful procedure (MD 0.04 minutes, 95% CI -0.01 to 0.09; 153 participants, 2 studies; low-certainty evidence) up to one hour compared to modified real-time B-mode ultrasound guidance. It is uncertain whether real-time B-mode ultrasound guidance has any effect on major haematomas compared to modified real-time B-mode ultrasound (very low-certainty evidence). Pseudoaneurysm, pain, and QoL were not reported. In-plane versus out-of-plane B-mode ultrasound In-plane real-time B-mode ultrasound guidance may lead to no difference in overall success rate (RR 1.00, 95% CI 0.96 to 1.05; 1051 participants, 8 studies; low-certainty evidence) and in time needed for a successful procedure (MD -0.06 minutes, 95% CI -0.16 to 0.05; 1134 participants, 9 studies; low-certainty evidence) compared to out-of-plane B-mode ultrasound up to one hour. It is uncertain whether in-plane real-time B-mode ultrasound guidance has any effect on first attempt success rate or major haematomas compared to out-of-plane B-mode ultrasound (very low-certainty evidence). Pseudoaneurysm, pain, and QoL were not reported. DUA versus palpation and landmarks DUA may lead to no difference in first attempt success rate (RR 1.01, 95% CI 0.90 to 1.14; 666 participants, 2 studies; low-certainty evidence) or overall success rate (RR 0.99, 95% CI 0.92 to 1.07; 666 participants, 2 studies; low-certainty evidence) and probably increases time needed for a successful procedure (MD 0.45 minutes, 95% CI 0.20 to 0.70; 500 participants, 1 study; moderate-certainty evidence) up to 72 hours compared to palpation and landmarks. Pseudoaneurysm, major haematomas, pain, and QoL were not reported. Oblique-axis versus long-axis in-plane B-mode ultrasound Oblique-axis in-plane B-mode ultrasound guidance may increase overall success rate (RR 1.27, 95% CI 1.05 to 1.53; 215 participants, 2 studies; low-certainty evidence) up to 72 hours compared to long-axis in-plane B-mode ultrasound. It is uncertain whether oblique-axis in-plane B-mode ultrasound guidance has any effect on first attempt success rate, time needed for a successful procedure, and major haematomas compared to long-axis in-plane B-mode ultrasound. Pseudoaneurysm, pain, and QoL were not reported. We are uncertain about effects in the following comparisons due to very low-certainty evidence and unreported outcomes: real-time B-mode ultrasound versus palpation and landmarks (axillary and dorsalis pedis arteries), real-time B-mode ultrasound versus near-infrared laser (radial artery), and dynamic versus static out-of-plane B-mode ultrasound (radial artery). AUTHORS'

conclusionsReal-time B-mode ultrasound guidance may improve first attempt success rate, overall success rate, and time needed for a successful procedure for radial artery catheterisation compared to palpation, or DUA. In addition, real-time B-mode ultrasound guidance probably decreases major haematomas compared to palpation. However, we are uncertain about the evidence on major haematomas and pain for other comparisons due to very low-certainty evidence and unreported outcomes. We are also uncertain about the effects on pseudoaneurysm and QoL for axillary and dorsalis pedis arteries catheterisation. Given that first attempt success rate and pseudoaneurysm are the most relevant outcomes for people who underwent arterial catheterisation, future studies must measure both. Future trials must be large enough to detect effects, use validated scales, and report longer-term follow-up.

Indexed as

ArteriesCatheterizationAdultHumansUltrasonography

Identifiers

PMID34637140
PMCPMC8507521
OpenAlexW3016394085

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.