Evidence map›Paper›PMID 34634295›Full record

ArticleJournal of neuroradiology = Journal de neuroradiologie2022

Absolute cerebral blood flow: Assessment with a novel low-radiation-dose dynamic CT perfusion technique in a swine model.

Pablo Abbona, Yixiao Zhao, Logan Hubbard, Shant Malkasian, Brooklynn Flynn, Sabee Molloi

Open access · greenAbstract read
In one paragraph

Article in Journal of neuroradiology = Journal de neuroradiologie, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Pablo AbbonaDepartment of Radiological Sciences(a), University of California, Irvine, Irvine, CA, 92697, United States of America.
Yixiao ZhaoDepartment of Radiological Sciences(a), University of California, Irvine, Irvine, CA, 92697, United States of America.
Logan HubbardDepartment of Radiological Sciences(a), University of California, Irvine, Irvine, CA, 92697, United States of America.
Shant MalkasianDepartment of Radiological Sciences(a), University of California, Irvine, Irvine, CA, 92697, United States of America.
Brooklynn FlynnDepartment of Radiological Sciences(a), University of California, Irvine, Irvine, CA, 92697, United States of America.
Sabee MolloiDepartment of Radiological Sciences(a), University of California, Irvine, Irvine, CA, 92697, United States of America. Electronic address: symolloi@hs.uci.edu.
University of California, Irvine · US

Funding

Training Program in Cardiovascular Applied Research and EntrepreneurshipT32HL116270 · NHLBI · UNIVERSITY OF CALIFORNIA-IRVINE · PI HUGHES, CHRISTOPHER C. W. · 2013 to 2022
$1.6M
NHLBI NIH HHS T32 HL116270
6 · The paper itself

Abstract

RATIONALE AND

objectivesTo validate the accuracy of a novel low-dose dynamic CT perfusion technique in a swine model using fluorescent microsphere measurement as the reference standard. MATERIALS AND

methodsContrast-enhanced dynamic CT perfusion was performed in five swine at baseline and following brain embolization. Reference microspheres and intravenous contrast (370 mg/ml iodine, 1 ml/kg) were injected (5 ml/s), followed by dynamic CT perfusion. Scan parameters were 320×0.5 mm, 100 kVp and 200 mA. On average, 47 contrast-enhanced volume scans were acquired per acquisition to capture the time attenuation curve. For each acquisition, only two systematically selected volume scans were used to quantify brain perfusion with first-pass analysis technique. The first volume scan was selected at the base, simulating bolus tracking, while the second volume at the peak of the time attenuation curve similar to a CT angiogram. Regional low-dose CT perfusion measurements were compared to the microsphere perfusion measurements with t-test, linear regression and Bland-Altman analysis. The radiation dose of the two-volume CT perfusion technique was determined.

resultsLow-dose CT perfusion measurements (P

conclusionsThe accuracy and repeatability of a low-dose dynamic CT perfusion technique was validated in a swine model. This technique has the potential for accurate diagnosis and follow up of stroke and vasospasm.

Indexed as

Myocardial Perfusion ImagingAngiographyAnimalsCerebrovascular CirculationContrast MediaHumansPerfusionSwineTomography, X-Ray ComputedContrast MediaAnimalBrainModelsMultidetector computed tomographyPerfusionStroke

Identifiers

PMID34634295
PMCPMC9231667
OpenAlexW3207490395

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.