Evidence map›Paper›PMID 34632626›Full record

ArticleMagnetic resonance in medicine2022

A 31-channel integrated "AC/DC" B

Jason P Stockmann, Nicolas S Arango, Thomas Witzel, Azma Mareyam, Charlotte Sappo, Jiazheng Zhou, Lucas Jenkins, Lincoln Craven-Brightman, Eugene Milshteyn, Mathias Davids and 10 more

Open access · bronzeAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 26 citations in OpenAlex.

  1. Magnetic resonance imaging.Science advances · 2026
    Review
  2. Correcting motion-related BScientific reports · 2026
    Article
  3. Article
  4. Article
  5. Accelerated Navigator for Rapid ∆BNMR in biomedicine · 2025
    Article
  6. Article
  7. Adaptable, wearable, and stretchable coils: A review.Magnetic resonance in medicine · 2025
    Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Real-time shimming with FID navigators.Magnetic resonance in medicine · 2022
    Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors at 6 institutions in 2 countries.

Jason P StockmannAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0001-8454-5347
Nicolas S ArangoDepartment of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.ORCID 0000-0001-9877-3092
Thomas WitzelAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Azma MareyamAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Charlotte SappoAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0002-7030-278X
Jiazheng ZhouMax-Planck Institute for Biological Cybernetics, High-Field Magnetic Resonance, Tübingen, Germany.ORCID 0000-0002-7114-5181
Lucas JenkinsAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Lincoln Craven-BrightmanAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Eugene MilshteynAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0003-0213-7003
Mathias DavidsAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0003-0217-9123
W Scott HogeAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Monika SliwiakAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Shahin NasrAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Boris KeilAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.ORCID 0000-0003-0805-8330
Elfar AdalsteinssonDepartment of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
Bastien GuerinAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Jacob K WhiteDepartment of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.
Kawin SetsompopAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Jonathan R PolimeniAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Lawrence L WaldAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
Harvard University · USMassachusetts General Hospital · USMassachusetts Institute of Technology · USBrigham and Women's Hospital · USMax Planck Institute for Biological Cybernetics · DEVanderbilt University · US

Funding

MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
Training and Dissemination CoreP41EB030006 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Berkin Bilgic · 2020 to 2026
$10.9M
Parallel Excitation Methods for High Field MRIR01EB006847 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI WALD, LAWRENCE L · 2007 to 2020
$5.4M
Improving Human fMRI through Modeling and Imaging Microvascular Dynamics: Administrative SupplementR01MH111419 · NIMH · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO · 2016 to 2020
$4.9M
Applications of high resolution fMRI in ultra-high field (7T) in revealing developmental disorders underlying amblyopiaR01EY030434 · NEI · MASSACHUSETTS GENERAL HOSPITAL · PI Shahin Nasr · 2020 to 2026
$3.8M
System Upgrade for Siemens 7T Human MRI SystemS10OD023637 · OD · MASSACHUSETTS GENERAL HOSPITAL · PI WALD, LAWRENCE L · 2017 to 2017
$2.0M
Open-source software and hardware tools for local B0 field controlU24EB028984 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI STOCKMANN, JASON P · 2019 to 2021
$964k
Improved imaging of deep brain nuclei with 7 Tesla MRI using comprehensive magnetic field monitoringR00EB021349 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI STOCKMANN, JASON P · 2018 to 2020
$747k
Combined shim-RF for improved high field MRIR21EB017338 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI WALD, LAWRENCE L · 2013 to 2014
$472k
Improved imaging of deep brain nuclei with 7 Tesla MRI using comprehensive magnetic field monitoring and compensationK99EB021349 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI STOCKMANN, JASON P · 2016 to 2017
$190k
Neuroimaging of deep brain stimulation patients using safe MRI excitationsK99EB019482 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI GUERIN, BASTIEN · 2015 to 2016
$188k
NEI NIH HHS R01 EY030434NIBIB NIH HHS K99 EB019482NIBIB NIH HHS K99 EB021349NIBIB NIH HHS P41 EB030006NIBIB NIH HHS R00 EB021349NIBIB NIH HHS R01 EB006847NIBIB NIH HHS R21 EB017338NIBIB NIH HHS U01 EB025162NIBIB NIH HHS U24 EB028984NIH HHS S10 OD023637NIMH NIH HHS R01 MH111419
6 · The paper itself

Abstract

purposeTo test an integrated "AC/DC" array approach at 7T, where B

methodsA close-fitting 7T 31-channel (31-ch) brain array was constructed and tested using combined Rx and ΔB

resultsThe SNR and average noise correlation were similar to the 31-ch reference array. Global and slice-optimized shimming provide 11% and 40% improvements respectively compared to baseline second-order spherical harmonic shimming. Birdcage transmit coil efficiency was similar for the reference and AC/DC array setups.

conclusionAdding ΔB

Indexed as

Image Processing, Computer-AssistedMagnetic Resonance ImagingBrainEcho-Planar ImagingPhantoms, ImagingRadio WavesSignal-To-Noise Ratio7 Teslaecho planar imagingfunctional MRIintegrated ΔB0/Rx coilIn vivo B0 shimmingmulti-coil shimming

Identifiers

PMID34632626
PMCPMC9899096
OpenAlexW3207582521

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.