Evidence map›Paper›PMID 34626242›Full record

ArticleEJNMMI physics2021

Quantitative Effect of Metal Artefact Reduction on CT-based attenuation correction in FDG PET/CT in patients with hip prosthesis.

Maarten Haemels, Delphine Vandendriessche, Jeroen De Geeter, James Velghe, Maxence Vandekerckhove, Frank De Geeter

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 56% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Maarten HaemelsDepartment of Nuclear Medicine, Algemeen Ziekenhuis Sint-Jan Brugge-Oostende, Ruddershove 10, 8000, Brugge, Belgium.
Delphine VandendriesscheDepartment of Nuclear Medicine, Algemeen Ziekenhuis Sint-Jan Brugge-Oostende, Ruddershove 10, 8000, Brugge, Belgium.
Jeroen De GeeterELEC Department, Faculty of Applied Sciences, Vrije Universiteit Brussel, Building K - Room K.6.55/D2, Pleinlaan 2, 1050, Brussel, Belgium.
James VelgheNuclear Technology Center, UHasselt, Campus Diepenbeek, Agoralaan Building D, 3590, Diepenbeek, Belgium.
Maxence VandekerckhoveDepartment of Orthopedics, Algemeen Ziekenhuis Sint-Jan Brugge-Oostende, Ruddershove 10, 8000, Brugge, Belgium.
Frank De GeeterDepartment of Nuclear Medicine, Algemeen Ziekenhuis Sint-Jan Brugge-Oostende, Ruddershove 10, 8000, Brugge, Belgium. frank.degeeter@azsintjan.be.ORCID http://orcid.org/0000-0002-4505-1237
AZ Sint-Jan · BEHasselt University · BEVrije Universiteit Brussel · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMetal artefact reduction (MAR) techniques still are in limited use in positron emission tomography/computed tomography (PET/CT). This study aimed to investigate the effect of Smart MAR on quantitative PET analysis in the vicinity of hip prostheses. MATERIALS AND

methodsActivities were measured on PET/CT images in 6 sources with tenfold activity concentration contrast to background, attached to the head, neck and the major trochanter of a human cadaveric femur, and in the same sources in similar locations after a hip prosthesis (titanium cup, ceramic head, chrome-cobalt stem) had been inserted into the femur. Measurements were compared between PET attenuation corrected using either conventional or MAR CT. In 38 patients harbouring 49 hip prostheses, standardized uptake values (SUV) in 6 periprosthetic regions and the bladder were compared between PET attenuation corrected with either conventional or MAR CT.

resultsUsing conventional CT, measured activity decreased with 2 to 13% when the prosthesis was inserted. Use of MAR CT increased measured activity by up to 11% compared with conventional CT and reduced the relative difference with the reference values to under 5% in all sources. In all regions, to the exception of the prosthesis shaft, SUV

conclusionsIn a realistic hip prosthesis phantom, Smart MAR restores quantitative accuracy by recovering counts in underestimated sources. In patient studies, Smart MAR increases SUV in all areas surrounding the prosthesis, most markedly in the femoral neck region. This proves that underestimation of activity in the PET image is the most prevalent effect due to metal artefacts in the CT image in patients with hip prostheses. Smart MAR increases SUV in the urinary bladder, indicating effects at a distance from the prosthesis.

Indexed as

Hip prosthesisMetal artefact reductionQuantitative accuracy

Identifiers

PMID34626242
PMCPMC8502194
OpenAlexW3155940226

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.