Evidence map›Paper›PMID 34621546›Full record

ReviewCritical care research and practice2021

Accuracy of Algorithms and Visual Inspection for Detection of Trigger Asynchrony in Critical Patients : A Systematic Review.

Monique Bandeira, Alícia Almeida, Lívia Melo, Pedro Henrique de Moura, Emanuelle Olympia Ribeiro Silva, Jakson Silva, Armèle Dornelas de Andrade, Daniella Brandão, Shirley Campos

Abstract readReview
In one paragraph

Review in Critical care research and practice, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Monique BandeiraPhysical Therapy Department, Universidade Federal de Pernambuco, Recife, Brazil.ORCID https://orcid.org/0000-0002-5616-232X
Alícia AlmeidaPhysical Therapy Department, Universidade Federal de Pernambuco, Recife, Brazil.ORCID https://orcid.org/0000-0002-1196-3756
Lívia MeloHospital Geral Otavio de Freitas, Recife, Brazil.ORCID https://orcid.org/0000-0003-4049-3391
Pedro Henrique de MouraPhysical Therapy Department, Universidade Federal de Pernambuco, Recife, Brazil.ORCID https://orcid.org/0000-0002-5585-5298
Emanuelle Olympia Ribeiro SilvaPhysical Therapy Department, Universidade Federal de Pernambuco, Recife, Brazil.ORCID https://orcid.org/0000-0002-1333-2181
Jakson SilvaPhysical Therapy Department, Universidade Federal de Pernambuco, Recife, Brazil.ORCID https://orcid.org/0000-0002-5697-0140
Armèle Dornelas de AndradePhysical Therapy Department, Universidade Federal de Pernambuco, Recife, Brazil.ORCID https://orcid.org/0000-0001-9430-4395
Daniella BrandãoPhysical Therapy Department, Universidade Federal de Pernambuco, Recife, Brazil.ORCID https://orcid.org/0000-0001-8805-6815
Shirley CamposPhysical Therapy Department, Universidade Federal de Pernambuco, Recife, Brazil.ORCID https://orcid.org/0000-0003-3079-8300

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to summarize the accuracy of the different methods for detecting trigger asynchrony at the bedside in mechanically ventilated patients.

methodA systematic review was conducted from 1990 to 2020 in PubMed, Lilacs, Scopus, and ScienceDirect databases. The reference list of the identified studies, reviews, and meta-analyses was also manually searched for relevant studies. The reference standards were esophageal pressure catheter and/or electrical activity of the diaphragm. Studies were assessed following the QUADAS-2 recommendations, while the review was prepared according to the PRISMA criteria.

resultsOne thousand one hundred and eleven studies were selected, and four were eligible for analysis. Esophageal pressure was the predominant reference standard, while visual inspection and algorithms/software comprised index tests. The trigger asynchrony, ineffective expiratory effort, double triggering, and reverse triggering were analyzed. Sensitivity and specificity ranged from 65.2% to 99% and 80% to 100%, respectively. Positive predictive values reached 80.3 to 100%, while the negative predictive values reached 92 to 100%. Accuracy could not be calculated for most studies.

conclusionAlgorithms/software validated directly or indirectly using reference standards present high sensitivity and specificity, with a diagnostic power similar to visual inspection of experts.

Identifiers

PMID34621546
PMCPMC8492248

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.