Evidence map›Paper›PMID 34621410›Full record

ArticleJournal of arrhythmia2021

Procedural outcome of lead explant and countertraction-assisted femoral lead extraction in Thai patients with cardiac implantable electronic device infection.

Jirarat Jiratham-Opas, Narawudt Prasertwitayakij, Teerapat Nantsupawat, Wanwarang Wongcharoen

Open access · goldAbstract read
In one paragraph

Article in Journal of arrhythmia, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Jirarat Jiratham-OpasDepartment of Internal Medicine Faculty of Medicine Chiang Mai University Chiang Mai Thailand.ORCID https://orcid.org/0000-0002-1971-7170
Narawudt PrasertwitayakijDepartment of Internal Medicine Faculty of Medicine Chiang Mai University Chiang Mai Thailand.ORCID https://orcid.org/0000-0002-7470-329X
Teerapat NantsupawatDepartment of Internal Medicine Faculty of Medicine Chiang Mai University Chiang Mai Thailand.ORCID https://orcid.org/0000-0002-3319-9066
Wanwarang WongcharoenDepartment of Internal Medicine Faculty of Medicine Chiang Mai University Chiang Mai Thailand.ORCID https://orcid.org/0000-0002-2418-329X
Chiang Mai University · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCardiac implantable electronic device (CIED) implantation rate has been increasing worldwide. Despite proper surgical technique and preincisional intravenous antibiotics, the incidence of infected CIED remains high and leads to serious complications. When encountered with CIED infection, complete CIED system removal is indicated. Several lead extraction approaches have shown a high success rate. However, the facilities are limited in Thailand. In our current practice, we perform lead extraction using the Dotter basket snare femoral approach as our primary method. There are no prior data on this countertraction-assisted transfemoral technique. Therefore, we aim to study the procedural outcome of countertraction-assisted transfemoral lead removal technique of CIED infection in Thai patients.

methodsPatients diagnosed with CIED infection and with a history of device infection were retrospectively included. Simple manual removal was performed. In case of failure, we proceeded with the modified countertraction-assisted transfemoral technique.

resultsThere were 35 patients in the study. The success rate was 94.3%. Most of the leads, 62.8%, were removed by simple manual traction. In the 37.1% who required further femoral approach lead extractions, procedural failure was observed in 5.7% and procedure-related adverse events in 5.6%. CIED infection-related death accounted for 5.7% and nosocomial infection-related death, 2.8%.

conclusionThe success rate of CIED infection lead explant and countertraction-assisted transfemoral lead extraction technique was high with small complications and can be performed without advanced facilities. However, the procedure required a main center with a cardiovascular thoracic surgery support team.

Indexed as

CIED infectioncountertraction‐assisted femoral lead extractionlead removal

Identifiers

PMID34621410
PMCPMC8485811
OpenAlexW3204016347

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.