ArticleBiomedical engineering online2021
Influence of posterior pedicle screw fixation at L4-L5 level on biomechanics of the lumbar spine with and without fusion: a finite element method.
Article in Biomedical engineering online, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it, 30 citations in OpenAlex.
- Comparative effectiveness of cortical bone trajectory screws and pedicle screws in the treatment of adjacent segment degeneration after lumbar fusion surgery: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2024Pooled it
- The effect of pedicle screw angle on stress distribution in lumbar spine fixation: an optimization approach based on finite element analysis.Journal of orthopaedic surgery and research · 2026Article
- The impact of pedicle screw transitional segment and thread distribution on postoperative rod-screw system failure : insights from clinical research and mechanical testing.Bone & joint research · 2026Article
- Evaluation of the porosity and structural stability of 3D-printed porous titanium pedicle screws using finite element analysis.Biomedical engineering letters · 2026Article
- Subsidence reduction effect of transforaminal lumbar interbody fusion (TLIF) with upper and lower open windows modified with lattice structure.Biomedical engineering letters · 2025Article
- Biomechanical effects of transforaminal endoscopic lumbar discectomy combined with spinal dynamic stabilization system use on adjacent segments: a finite element analysis.BMC musculoskeletal disorders · 2025Article
- Impact of screw tip design on screw anchorage: mechanical testing and numerical simulation.Journal of orthopaedic surgery and research · 2024Article
- Intraoperative capsule protection can reduce the potential risk of adjacent segment degeneration acceleration biomechanically: an in silico study.Journal of orthopaedic surgery and research · 2024Article
- Finite element biomechanical analysis of 3D printed intervertebral fusion cage in osteoporotic population.BMC musculoskeletal disorders · 2024Article
- Finite element analysis comparing a PEEK posterior fixation device versus pedicle screws for lumbar fusion.Journal of orthopaedic surgery and research · 2023Article
- Identification of screw spacing on pediatric hip locking plate in proximal femoral osteotomy.Physical and engineering sciences in medicine · 2023Article
- Biomechanical properties of lumbar vertebral ring apophysis cage under endplate injury: a finite element analysis.BMC musculoskeletal disorders · 2023Article
- Optimization of in-brace corrective force in adolescents with Lenke type 5 curve using finite element model.Journal of orthopaedic surgery and research · 2023Article
- Biomechanical evaluation of different sizes of 3D printed cage in lumbar interbody fusion-a finite element analysis.BMC musculoskeletal disorders · 2023Article
- A comparative analysis of using cage acrossing the vertebral ring apophysis in normal and osteoporotic models under endplate injury: a finite element analysis.Frontiers in bioengineering and biotechnology · 2023Article
- Application of dual-trajectory screws in revision surgery for lumbar adjacent segment disease: a finite element study.Journal of orthopaedic surgery and research · 2022Article
- Biomechanical characteristics of 2 different posterior fixation methods of bilateral pedicle screws: A finite element analysis.Medicine · 2022Article
- Lumbar facet joint stabilization for symptomatic spinal degenerative disease: A systematic review of the literature.Journal of craniovertebral junction & spineReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPosterior pedicle screw (PS) fixation, a common treatment method for widespread low-back pain problems, has many uncertain aspects including stress concentration levels, effects on adjacent segments, and relationships with physiological motions. A better understanding of how posterior PS fixation affects the biomechanics of the lumbar spine is needed. For this purpose, a finite element (FE) model of a lumbar spine with posterior PS fixation at the L4-L5 segment level was developed by partially removing facet joints (FJs) to imitate an actual surgical procedure. This FE study aimed to investigate the influence of the posterior PS fixation system on the biomechanics of the lumbar spine before and after fusion by determining which physiological motions have the most increase in posterior instrumentation (PI) stresses and FJ loading.
resultsIt was determined that posterior PS fixation increased FJ loading by approximately 35% and 23% at the L3-L4 adjacent level with extension and lateral bending motion, respectively. This increase in FJ loading at the adjacent level could point to the possibility that adjacent segment disease has developed or progressed after posterior lumbar interbody fusion. Furthermore, analyses of peak von Mises stresses on PI showed that the maximum PI stresses of 272.1 MPa and 263.7 MPa occurred in lateral bending and flexion motion before fusion, respectively.
conclusionsThe effects of a posterior PS fixation system on the biomechanics of the lumbar spine before and after fusion were investigated for all physiological motions. This model could be used as a fundamental tool for further studies, providing a better understanding of the effects of posterior PS fixation by clearing up uncertain aspects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.