Evaluation of the clinical performance of a magnetic force-assisted electrochemical immunoassay for the detection of SARS-CoV-2 antigens.

Sung Jin Jo, Sang-Hyun Shin, Jungrok Kim, Seungok Lee, Jehoon Lee

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Sung Jin JoDepartment of Laboratory Medicine, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.ORCID 0000-0001-5216-7732
Sang-Hyun ShinDepartment of Laboratory Medicine, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Jungrok KimDepartment of Laboratory Medicine, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Seungok LeeDepartment of Laboratory Medicine, Incheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Incheon, Republic of Korea.
Jehoon LeeDepartment of Laboratory Medicine, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.ORCID 0000-0002-1401-1478
The Catholic University of Korea Seoul St. Mary's Hospital · KRThe Catholic University of Korea Incheon St. Mary's Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rapid antigen (Ag) tests for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) provide quick results, do not require specialized technical skills or infrastructure, and can be used as a point-of-care method to prevent the spread of coronavirus disease (COVID-19). The performance of a magnetic force-assisted electrochemical immunoassay-based test, namely the MARK-B COVID-19 Ag test (BBB, Sungnam, Republic of Korea), was evaluated using 170 nasopharyngeal swab specimens and compared to that of RT-PCR and commercial rapid Ag test (STANDARD Q COVID-19 Ag Test, SD Biosensor, Suwon-si, Republic of Korea). The overall sensitivity and specificity of the MARK-B test were 90.0% (95% CI 79.4%-96.2%) and 99.0% (95% CI 95.0%-99.9%), respectively, with a kappa coefficient of 0.908. The correlations between the electrical current values of MARK-B and the Ct values of RT-PCR were -0.898 (E gene, 95% CI -0.938 to -0.834) and -0.914 (RdRp gene, 95% CI -0.948 to -0.860), respectively. The limit of detection of the MARK-B was measured using the viral culture reference samples and found to be 1 x 102 pfu/mL. The magnetic force-assisted electrochemical immunoassay-based Ag test can be used to rapidly detect SARS-CoV-2 infections, and the corresponding fully automated portable device can provide easy readability and semi-quantitative results.

Indexed as

COVID-19COVID-19 Serological TestingElectrochemical TechniquesMagnetic FieldsAntigens, ViralHumansImmunoassayRepublic of KoreaSARS-CoV-2Antigens, Viral

Identifiers

PMID34618868
PMCPMC8496795
OpenAlexW3204574912

What OpenQuestion holds

Textmetadata
LicenceCC BY