Evidence map›Paper›PMID 34618848›Full record

ArticlePloS one2021

Can the design of the instruments used for undersized osteotomies influence the initial stability of implants installed in low-density bone? An in vitro pilot study.

Márcio de Carvalho Formiga, Arthur Felipe Gehrke, João Paulo De Bortoli, Sergio Alexandre Gehrke

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 2 countries.

Márcio de Carvalho FormigaProfessor of the Implantology Program, UniSociesc, Florianópolis, Brazil.ORCID 0000-0002-4093-2203
Arthur Felipe GehrkeDepartment of Mathematics, Universidade Federal de Santa Maria, Santa Maria, Brazil.
João Paulo De BortoliProfessor of the Implantology Program, Associação Paulista dos Cirurgiões Dentistas-APCD, São Bernardo do Campo, Brazil.
Sergio Alexandre GehrkeCoordinator of Postgraduate Program in Implantology, Bioface Institute/UCAM/PgO, Montevideo, Uruguay.ORCID 0000-0002-5863-9101
Associação Paulista de Medicina · BRUniversidad de Murcia · ESUniversidade Federal de Santa Maria · BRUniversidade Sociedade Educacional de Santa Catarina · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe aims of this study were to compare the initial implant stability obtained using four different osteotomy techniques in low-density synthetic bone, to evaluate the instrument design in comparison to the implant design, and to determinate a possible correlation between the insertion torque and initial stability quotient (ISQ). MATERIALS AND

methodsFour groups were identified in accordance with the osteotomy technique used (n = 10 implants per group): group G1, osteotomy using the recommended drilling sequence; group G2, osteotomy using an undersized compactor drill; group G3, osteotomy using an undersized drill; and group G4, osteotomy using universal osseodensification drills. Two polyurethane blocks were used: block 1, with a medullary portion of 10 pounds per cubic foot (PCF 10) and with a 1 mm cortical portion of PCF 40, and block 2, with a medullary of PCF 15 and with a 2 mm cortical portion of PCF 40. Tapered implants of 4 mm in diameter and 11 mm in length were used. The insertion torque (IT) and ISQ were measured. The dimensions of the final instrument used in each group and the dimensions of the implant were used to calculate the total area of each part, and these data were compared.

resultsDifferences between the four groups were found for IT and ISQ values depending on the technique used for the osteotomy in the two synthetic bone models (p < 0.0001). All groups showed lower values of initial stability in block 1 than in block 2.

conclusionsUndersized osteotomies with instruments designed according to the implant body significantly increased the initial stability values compared to beds prepared with universal drills and using the drilling sequence standardized by the manufacturer.

Indexed as

Prostheses and ImplantsBone and BonesBone DensityBone Diseases, MetabolicBrazilDental Implantation, EndosseousHumansOsteotomyPilot ProjectsPolyurethanesTorquePolyurethanes

Identifiers

PMID34618848
PMCPMC8496820
OpenAlexW3201856632

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.