Evidence map›Paper›PMID 34612175›Full record

ArticleJournal of occupational and environmental hygiene2021

Particle-phase collection efficiency of the OVS and IFV Pro personal pesticide samplers.

Shaunae Alex, Matthew Sovers, Patrick T O'Shaughnessy

Abstract read
In one paragraph

Article in Journal of occupational and environmental hygiene, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Shaunae AlexDepartment of Occupational and Environmental Health, College of Public Health, The University of Iowa, Iowa City, Iowa.
Matthew SoversDepartment of Occupational and Environmental Health, College of Public Health, The University of Iowa, Iowa City, Iowa.
Patrick T O'ShaughnessyDepartment of Occupational and Environmental Health, College of Public Health, The University of Iowa, Iowa City, Iowa.ORCID 0000-0001-9173-2722

Funding

Pulmonary Toxicology Facility CoreP30ES005605 · NIEHS · UNIVERSITY OF IOWA · PI Brandi Janssen · 1990 to 2026
$40.5M
The Heartland Center for Occupational Health and Safety Education and Research CenterT42OH008491 · OH · UNIVERSITY OF IOWA · PI O'SHAUGHNESSY, PATRICK T · 2005 to 2025
$31.7M
ACL HHS T42OH008491NIEHS NIH HHS P30 ES005605NIOSH CDC HHS T42 OH008491
6 · The paper itself

Abstract

The inhalable aerosol sampling criterion has been developed to characterize the efficiency of particles entering the nose and/or mouth. However, pesticides can exist in the air in both vapor and particulate phases, which complicates exposure assessments. The American Conference of Governmental Industrial Hygienists (ACGIH) has established an IFV (inhalable fraction and vapor) endnote for chemicals such as many pesticides that need to be evaluated for both their inhalable fraction and vapor concentrations to fully characterize worker exposures. The purpose of this study was to evaluate the particle-phase collection efficiency of a commonly-used pesticide sampler, the OSHA Versatile Sampler (OVS) as well as a recently developed sampler, the IFV Pro. The OVS was not designed as an inhalable aerosol sampler, whereas the IFV Pro contains a sampling head scaled to that of the Institute of Medicine (IOM) sampler, which is known to closely follow the inhalable sampling criterion. Laboratory experiments involving a vertical-flow, low-velocity scheme, and finely graded test dusts with known median aerodynamic diameter were used to determine sampler collection efficiencies. The collection efficiency of the OVS was evaluated as recommended by the manufacturer and after two modifications made to potentially improve its collection efficiency. The OVS was found to substantially under-sample relative to the inhalable criterion, and the two modifications did not provide substantial improvements to the original configuration. Conversely, the collection efficiency of the IFV Pro was found to compare closely to that of the IOM, although collecting 9% more mass. When applied side-by-side with the OVS sampler in a chamber into which ethylene glycol was sprayed as a proxy for a pesticide, the IFV Pro collected an average of 1.9-fold more mass than the OVS for the same flow rate and sample time.

Indexed as

Air Pollutants, OccupationalOccupational ExposurePesticidesAerosolsEnvironmental MonitoringInhalation ExposureParticle SizeUnited StatesUnited States Occupational Safety and Health AdministrationAerosolsAir Pollutants, OccupationalPesticidesEfficiencyinhalablepesticidessamplers

Identifiers

PMID34612175
PMCPMC8755619

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.