ArticleCardiovascular revascularization medicine : including molecular interventions2022
Adverse Events Following Transcatheter Edge-to-Edge Repair (TEER) Using MitraClip: Lessons Learned From the Manufacturer and User Facility Device Experience (MAUDE) Registry.
Article in Cardiovascular revascularization medicine : including molecular interventions, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Article
- Adverse events after transcatheter edge-to-edge repair: descriptive post-marketing surveillance analysis of MitraClip and PASCALJournal of thoracic disease · 2026Article
- Death incidents following transcatheter edge-to-edge repair (TEER) with the MitraClip device: analysis of 10-years post-marketing death reports from the Manufacturer and User Facility Device Experience (MAUDE) registry.BMC cardiovascular disorders · 2025Article
- Disparities in Health and Healthcare: Impact of Race on Resource Utilization and Costs Following Transcatheter Edge-to-Edge Repair.Cardiovascular revascularization medicine : including molecular interventions · 2023Article
- Cardiogenic Shock Secondary to Acute Mitral Regurgitation With Nonischemic Etiology Successfully Stabilized by Transcatheter Intervention.CASE (Philadelphia, Pa.) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
objectiveThe MitraClip from Abbott is FDA approved intracardiac implantable device for transcatheter edge-to-edge repair (TEER). Despite a few previously published studies, there is limited safety data for its use in clinical practice, hence, we designed this study using data obtained from a safety nationwide database to demonstrate the safety profile of MitraClip.
methodsThe first two of the five authors independently queried all reported adverse events from the United State Food and Drug Administration [FDA] Manufacturer and User Facility Device Experience [MAUDE] registry from January 2014 to December 2020. The primary end point was trend in reported fatal events obtained from this database. The secondary end points included the causes of reported nonfatal reports from the MAUDE registry. The trend of reported fatal events was assessed using the Cochran Armitage trend test over the period of the study.
resultsDuring the study period, subjects included 3370 patients whose MitraClip-associated adverse events were reported and captured by MAUDE registry. Of these, 211 were fatal and 3159 nonfatal events. Fatal event reports resulted deaths and reported nonfatal events were from injuries and device system malfunction. This study demonstrated an initial upward trend from 2014 to 2015 then a subsequent statistically significant downward trend in reported fatal events from 2015 to 2020 (Cochran-Armitage test P = 0.039). The peak proportion of reported fatal events occurred in 2015, (n = 44; representing 1.25% of reported adverse events) and lowest proportion of reported fatal events took place in 2020 (n = 19; representing 0.56% of reported adverse events). The most reported nonfatal events were from malfunctioning of MitraClip system (n = 1170; representing 37% of reported nonfatal events), new unremarkable repolarization abnormalities on periprocedural EKG (n = 864; representing 27% of reported nonfatal events), leaflet rupture (n = 651; representing 21% of reported nonfatal events), and cardiogenic shock (n = 170; representing 5% of reported nonfatal events).
conclusionsThis analysis of the MAUDE Registry indicated, especially within the confines of this study's limitations and poor data quality of information, an apparent downward trend of reported fatal events over the study period. Even though conclusive attributions cannot be made regarding this important finding, perhaps, this points to early evidence of a potential institutional or operator learning curve with this device. However, in view of the inferior quality of the data accrued from the MAUDE Registry, more high-precision studies are needed to better understand these changes, as the utility of MitraClip, becomes more established in clinical practice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.