Evidence map›Paper›PMID 34609623›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2022

A three-dimensional biomodel of type A aortic dissection for endovascular interventions.

Mamoru Arakawa, Hirohito Sumikura, Homare Okamura, Atsushi Miyagawa, Akihiko Homma, Atsushi Yamaguchi

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.1field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. A three-dimensional model of aortic dissection for hybrid surgical simulation and training.Interdisciplinary cardiovascular and thoracic surgery · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Mamoru ArakawaDepartment of Cardiovascular Surgery, Jichi Medical University, Saitama Medical Center, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan. mamoru35@jichi.ac.jp.ORCID http://orcid.org/0000-0002-7879-4280
Hirohito SumikuraSchool of Science and Engineering, Tokyo Denki University, Saitama, Japan.
Homare OkamuraDepartment of Cardiovascular Surgery, Jichi Medical University, Saitama Medical Center, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan.
Atsushi MiyagawaDepartment of Cardiovascular Surgery, Jichi Medical University, Saitama Medical Center, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan.
Akihiko HommaSchool of Science and Engineering, Tokyo Denki University, Saitama, Japan.
Atsushi YamaguchiDepartment of Cardiovascular Surgery, Jichi Medical University, Saitama Medical Center, 1-847 Amanuma, Omiya-Ku, Saitama, 330-8503, Japan. yamaatsu@omiya.jichi.ac.jp.
Jichi Medical University · JPTokyo Denki University · JP

Funding

JSPS KAKENHI JP 21K16501
6 · The paper itself

Abstract

Thoracic endovascular aortic repair is widely used for type B aortic dissection. However, there is no favorable stent-graft for type A aortic dissection. A significant limitation for device development is the lack of an experimental model for type A aortic dissection. We developed a novel three-dimensional biomodel of type A aortic dissection for endovascular interventions. Based on Digital Imaging and Communication in Medicine data from the computed tomography image of a patient with a type A aortic dissection, a three-dimensional biomodel with a true lumen, a false lumen, and an entry tear located at the ascending aorta was created using laser stereolithography and subsequent vacuum casting. The biomodel was connected to a pulsatile mock circuit. We conducted four tests: an endurance test for clinical hemodynamics, wire insertion into the biomodel, rapid pacing, and simulation of stent-graft placement. The biomodel successfully simulated clinical hemodynamics; the target blood pressure and cardiac output were achieved. The guidewire crossed both true and false lumens via the entry tear. The pressure and flow dropped upon rapid pacing and recovered after it was stopped. This simulation biomodel detected decreased false luminal flow by stent-graft placement and detected residual leak. The three-dimensional biomodel of type A aortic dissection with a pulsatile mock circuit achieved target clinical hemodynamics, demonstrated feasibility for future use during the simulated endovascular procedure, and evaluated changes in the hemodynamics.

Indexed as

Aortic Aneurysm, ThoracicAortic DissectionBlood Vessel Prosthesis ImplantationEndovascular ProceduresAorta, ThoracicHumansStentsTreatment OutcomePulsatile mock circuitThoracic endovascular aortic repairThree-dimensional printed modelType A aortic dissection

Identifiers

PMID34609623
OpenAlexW3203863313

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.