Evidence map›Paper›PMID 34603984›Full record

ArticleQuantitative imaging in medicine and surgery2021

Ultra-high resolution computed tomography of joints: practical recommendations for acquisition protocol optimization.

Pedro Augusto Gondim Teixeira, Nicolas Villani, Malik Ait Idir, Edouard Germain, Charles Lombard, Romain Gillet, Alain Blum

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Pedro Augusto Gondim TeixeiraGuilloz Imaging department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Nicolas VillaniRadioprotection Unit, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Malik Ait IdirGuilloz Imaging department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Edouard GermainGuilloz Imaging department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Charles LombardGuilloz Imaging department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Romain GilletGuilloz Imaging department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Alain BlumGuilloz Imaging department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Centre de Recherche en Automatique de Nancy · FRCentre Hospitalier Régional et Universitaire de Nancy · FRImagerie Adaptative Diagnostique et Interventionnelle · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo assess the influence on the spatial resolution of various Ultra-high-resolution computed tomography (CT) parameters and provide practical recommendations for acquisition protocol optimization in musculoskeletal imaging.

methodsAll acquisitions were performed with an Ultra-high resolution scanner, and variations of the following parameters were evaluated: field-of-view (150-300 mm), potential (80-140 KVp), current (25-250 mAs), focal spot size (0.4×0.5 to 0.8×1.3 mm

resultsUnder the conditions studied, the factor that most intensely influenced spatial resolution was the matrix size (additional visualization of up to 8 lp/cm). Increasing the matrix from 512×512 to 2048×2048 led to a 28.2% increase in TTF10% values with a high-dose protocol and a 5.6% increase with a low-dose protocol with no change in the number of visually distinguishable line pairs. The second most important factor affecting spatial resolution was the tube output (29.6% TTF10% gain and 5 additional lp/cm visualized), followed by the reconstruction algorithm choice and lateral displacement (both with a 4 lp/cm gain). Decreasing the slice thickness from 0.5 to 0.25 mm, led to an increase of 3 lp/cm (from 17 to 20 lp/cm) and a 17.3% increase in TTF10% values with no change in the "in-plane" spatial resolution.

conclusionsThis study provides practical recommendations for spatial resolution optimization using Ultra-high-resolution CT.

Indexed as

Computed tomography (CT)musculoskeletal imagingradiation doserecommendationsspatial resolution

Identifiers

PMID34603984
PMCPMC8408802
OpenAlexW3167279660

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.