Evidence map›Paper›PMID 34603003›Full record

ArticleFrontiers in neurorobotics2021

Control of Newly-Designed Wearable Robotic Hand Exoskeleton Based on Surface Electromyographic Signals.

Ke Li, Zhengzhen Li, Haibin Zeng, Na Wei

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neurorobotics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
3.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 35 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Simultaneous and Proportional Myoelectric Control of Multiple Degrees of Freedom in Individuals With Chronic Hemiparesis.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Ke LiLaboratory of Rehabilitation Engineering, Research Center of Intelligent Medical Engineering, School of Control Science and Engineering, Shandong University, Jinan, China.
Zhengzhen LiLaboratory of Rehabilitation Engineering, Research Center of Intelligent Medical Engineering, School of Control Science and Engineering, Shandong University, Jinan, China.
Haibin ZengDepartment of Radiotherapy, Suzhou Dushu Lake Hospital, Suzhou, China.
Na WeiDepartment of Geriatrics, Qilu Hospital, Shandong University, Jinan, China.
Shandong University · CNQilu Hospital of Shandong University · CNThe Fourth Affiliated Hospital of Soochow University (Suzhou Dushu Lake Hospital)

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The human hand plays a role in a variety of daily activities. This intricate instrument is vulnerable to trauma or neuromuscular disorders. Wearable robotic exoskeletons are an advanced technology with the potential to remarkably promote the recovery of hand function. However, the still face persistent challenges in mechanical and functional integration, with real-time control of the multiactuators in accordance with the motion intentions of the user being a particular sticking point. In this study, we demonstrated a newly-designed wearable robotic hand exoskeleton with multijoints, more degrees of freedom (DOFs), and a larger range of motion (ROM). The exoskeleton hand comprises six linear actuators (two for the thumb and the other four for the fingers) and can realize both independent movements of each digit and coordinative movement involving multiple fingers for grasp and pinch. The kinematic parameters of the hand exoskeleton were analyzed by a motion capture system. The exoskeleton showed higher ROM of the proximal interphalangeal and distal interphalangeal joints compared with the other exoskeletons. Five classifiers including support vector machine (SVM), K-near neighbor (KNN), decision tree (DT), multilayer perceptron (MLP), and multichannel convolutional neural networks (multichannel CNN) were compared for the offline classification. The SVM and KNN had a higher accuracy than the others, reaching up to 99%. For the online classification, three out of the five subjects showed an accuracy of about 80%, and one subject showed an accuracy over 90%. These results suggest that the new wearable exoskeleton could facilitate hand rehabilitation for a larger ROM and higher dexterity and could be controlled according to the motion intention of the subjects.

Indexed as

exoskeletongesture recognitionhand rehabilitationsurface electromyographywearable robots

Identifiers

PMID34603003
PMCPMC8480391
OpenAlexW3201611008

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked