Evidence map›Paper›PMID 34602721›Full record

ArticleBuilding and environment2021

Respiratory infection risk-based ventilation design method.

Jarek Kurnitski, Martin Kiil, Pawel Wargocki, Atze Boerstra, Olli Seppänen, Bjarne Olesen, Lidia Morawska

Abstract read
In one paragraph

Article in Building and environment, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Article
  2. Mitigating indoor risk of airborne infections using COJournal of environmental health science & engineering · 2026
    Article
  3. Article
  4. Carbon dioxide guidelines for indoor air quality: a review.Journal of exposure science & environmental epidemiology · 2024
    Review
  5. Article
  6. COJournal of infection and public health · 2023
    Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. The Influence of Ventilation Measures on the Airborne Risk of Infection in Schools: A Scoping Review.International journal of environmental research and public health · 2023
    Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. A novel COBuilding and environment · 2022
    Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jarek KurnitskiDepartment of Civil Engineering and Architecture, Tallinn University of Technology, Tallinn, Estonia.
Martin KiilDepartment of Civil Engineering and Architecture, Tallinn University of Technology, Tallinn, Estonia.
Pawel WargockiInternational Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Denmark.
Atze BoerstraBBA Binnenmilieu, the Netherlands.
Olli SeppänenNordic Ventilation Group, SCANVAC, Scandinavian Federation of Heating, Ventilation and Sanitary Engineering Associations in Denmark, Finland, Iceland, Norway and, Sweden.
Bjarne OlesenInternational Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Denmark.
Lidia MorawskaInternational Laboratory for Air Quality and Heath, Queensland University of Technology, Brisbane, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A new design method is proposed to calculate outdoor air ventilation rates to control respiratory infection risk in indoor spaces. We propose to use this method in future ventilation standards to complement existing ventilation criteria based on the perceived air quality and pollutant removal. The proposed method makes it possible to calculate the required ventilation rate at a given probability of infection and quanta emission rate. Present work used quanta emission rates for SARS-CoV-2 and consequently the method can be applied for other respiratory viruses with available quanta data. The method was applied to case studies representing typical rooms in public buildings. To reduce the probability of infection, the total airflow rate per infectious person revealed to be the most important parameter to reduce the infection risk. Category I ventilation rate prescribed in the EN 16798-1 standard satisfied many but not all type of spaces examined. The required ventilation rates started from about 80 L/s per room. Large variations between the results for the selected case studies made it impossible to provide a simple rule for estimating the required ventilation rates. Consequently, we conclude that to design rooms with a low infection risk the newly developed ventilation design method must be used.

Indexed as

Airborne pathogensCOVID-19Design methodEvent reproduction numberQuanta emissionRespiratory infectionVentilation criteriaVentilation standards

Identifiers

PMID34602721
PMCPMC8462055

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.