Evidence map›Paper›PMID 34596359›Full record

ArticleOrthopaedic surgery2021

A New Technique for Placement of Blocking Screws and its Mechanical Effect on Stability of Tibia Fractures with Distal Fragments after Insertion of Small-Diameter Intramedullary Nails.

Cong-Ming Zhang, Liang Sun, Qian Wang, Qiang Huang, Hua Lin, Ning Duan, Chen-Chen Zhang, Teng Ma, Han-Zhong Xue, Kun Zhang and 1 more

Abstract readComparative Study
In one paragraph

Article in Orthopaedic surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Cong-Ming ZhangDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.ORCID https://orcid.org/0000-0003-2651-2904
Liang SunDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Qian WangDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Qiang HuangDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Hua LinDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Ning DuanDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Chen-Chen ZhangDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Teng MaDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Han-Zhong XueDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Kun ZhangDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.
Zhong LiDepartment of Orthopaedics and Traumatology, Xi'an Jiaotong University College of Medicine, Hong-Hui Hospital, Xi'an, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo design a novel blocking screws (BSs) geometry and insertion method to treat distal tibia fracture with nailing and comparison of mechanical properties of novel and traditional screws.

methodsTwenty-one synthetic left tibiae were sectioned to obtain 21 distal segments measuring 55 mm. Intramedullary (IM) 9-mm tibial nails were advanced to 6 mm from the ankle joint. Two transverse and one anterior-posterior (AP) locking screws were inserted. Both medial-lateral (ML) BSs were placed 10 mm from the topmost interlocking screw. A custom-made jig assisted in placing the novel and traditional BSs. The time spent in placing each BS was recorded. All the samples were repaired with an IM nail and without BSs, with two traditional BSs, and with two novel BSs. An initial loading from -150 to +150 N was applied to specimens in the ML direction at 185 mm from the nail end, followed by cyclic loading of the same for 10,000 cycles with failure-to-test loading of 350 N in the ML direction. The maximum displacement was measured at 80 mm from the nail end and recorded under initial loading. The damage of two kinds of BSs to the nail was recorded.

resultsCompared with average 5.21 min of the time of placing a traditional BS, the time spent in positioning a novel BS on the fracture model was 2.53 min. In the distal bone-implant constructs (BICs), the addition of traditional BSs decreased the maximum displacement of the BICs by 26.2%. The addition of the novel BSs decreased the displacement by 28.9%. All constructs survived 10,000 cycles without hardware deformation. The failure rate of the control group was significantly greater than that of the traditional group; however, the novel group was similar to the traditional group. The damage of the traditional BS to the nail was greater than that of the novel one.

conclusionsThe novel and traditional BSs are comparably effective for increasing the primary mechanical stability of distal metaphyseal fractures after nailin. However, compared to the placement of a traditional BS, implanting a novel BS took more less time and caused less damage to the nail. Additionally, the most obvious advantage of the novel BS design and insertion technology was that the pressure and distance between it and the IM nail could be controlled by rotating the screw. These advantages of the novel BS will be beneficial for clinical application.

Indexed as

Bone NailsBone ScrewsMaterials TestingBiomechanical PhenomenaCadaverFracture Fixation, IntramedullaryHumansTibial FracturesBiomechanical evaluationDistal tibial fracturesNovel blocking screwSmall-diameter intramedullary nailingUnstable fractures

Identifiers

PMID34596359
PMCPMC8528988

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.