Evidence map›Paper›PMID 34596083›Full record

ArticleJournal of the Chinese Medical Association : JCMA2021

Biomechanical comparisons of different diagonal screw designs in a novel embedded calcaneal slide plate.

Shun-Ping Wang, Wei-Yi Lai, Yi-Yin Lin, Tzu-Wei Lin, Ming-Tzu Tsai, Yi-Ping Yang, Cheng-En Hsu, Chao-Ping Chen, Cheng-Hung Lee, Kuo-Chih Su

Open access · hybridAbstract read
In one paragraph

Article in Journal of the Chinese Medical Association : JCMA, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 5 institutions in 1 country.

Shun-Ping WangDepartment of Orthopedics, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
Wei-Yi LaiDepartment of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
Yi-Yin LinDepartment of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
Tzu-Wei LinDepartment of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
Ming-Tzu TsaiDepartment of Biomedical Engineering, Hungkuang University, Taichung, Taiwan, ROC.
Yi-Ping YangDepartment of Medical Research, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
Cheng-En HsuDepartment of Orthopedics, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
Chao-Ping ChenDepartment of Orthopedics, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
Cheng-Hung LeeDepartment of Orthopedics, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
Kuo-Chih SuDepartment of Biomedical Engineering, Hungkuang University, Taichung, Taiwan, ROC.
Taipei Veterans General Hospital · TWTaichung Veterans General Hospital · TWHungkuang University · TWNational Chung Hsing University · TWTunghai University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMedial displacement calcaneal osteotomy (MDCO) is frequently used for the surgical correction of flatfoot. This study aims to investigate the biomechanical effect of the different diagonal screw design on a novel-designed embedded calcaneal plate for MDCO using finite element analysis (FEA), mechanical test and digital image correlation (DIC) measurement.

methodsFour groups according to the varied implanted plate were set as control group (Group 1), non-diagonal screw (Group 2), one-diagonal screw (Group 3), and two-diagonal screws groups (Group 4). For FEA, A 450 N load was applied to on the anterior process of the calcaneus from top to bottom. Observational indices included the stress on the cortical and cancellous bone of the calcaneus surrounding the implant, the plate itself as well as screws, and the displacement of the overall structure. In addition, this study also used in vitro biomechanics test to investigate the stiffness of the structure after implantation, and used DIC to observe the displacement of the calcaneus structure after external force.

resultsUnder a simulated load in FEA, there are significant overall instability and high stress concentration on the calcaneal surrounding host bone and the plate/screws system, respectively, in group 2 compared with other groups. Regard to the mechanical testing with DIC system, significant increased rotation stability, maximum force and stiffness with the addition of diagonal screws. In comparison to Group 2, the increase of 112% and 157% in maximum force as well as 104% and 176% in stiffness were found in Group 3 and 4, respectively.

conclusionFor reducing stress concentration and enhancing overall stability, more than one-diagonal screw design is recommended and two-diagonal screws design will be superior. This study provided biomechanical references for further calcaneal implants design to prevent clinical failure after MDCO.

Indexed as

Bone PlatesBone ScrewsBiomechanical PhenomenaFinite Element AnalysisFracture Fixation, InternalHeel SpurHumansOsteotomyWeight-Bearing

Identifiers

PMID34596083
PMCPMC12966173
OpenAlexW3204674436

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.