ArticleHealth physics2021
Organ Dose Reconstruction Applicable for a Japanese Nuclear Worker Cohort: J-EPISODE.
Article in Health physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Construction of new polygon mesh-type phantoms based on adult Japanese voxel phantoms.PloS one · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
abstractAn evaluation of cancer risk based on organ-absorbed dose is underway for the Japanese Epidemiological Study on Low-Dose Radiation Effects (J-EPISODE), which has analyzed health effects in association with radiation exposure evaluated with the personal dose equivalent Hp(10). Although the concept of effective dose and its operational definition of Hp(10) are widely used for radiological protection purposes, effective dose is not recommended for epidemiological evaluation. Organ-absorbed dose was instead adopted for the IARC 15-Country Collaborative study (15-Country study), the International Nuclear Workers Study (INWORKS), the Mayak worker study, and the Life Span Study (LSS) of atomic bomb survivors. The reconstruction method in J-EPISODE followed in principle the approach adopted in the 15-Country Study. As part of the approach of J-EPISODE, a conversion factor from photon dosimeter reading to air kerma was developed using dosimeter response data, which were measured by the experiment using an anthropomorphic phantom, and it was confirmed that the 15-Country study's assumption of photon energy and geometry distribution in a work environment applied to Japanese nuclear workers. This article focuses on a method for reconstructing the conversion factor from photon dosimeter reading to organ-absorbed photon dose for a Japanese nuclear worker cohort. The model for estimating the conversion factor was defined under the assumption of a lognormal distribution from three concerned bias factors: (1) a dosimeter reading per air kerma, i.e., dosimeter response; (2) an organ-absorbed dose per air kerma; and (3) a factor relating to the differences in dose concepts and calibration practices between the roentgen dosimeter era and the present. Dosimeter response data were cited from the companion paper. Data on organ-absorbed photon dose per air kerma were estimated using a voxel phantom with the average Japanese adult male height and weight. The bias factor for the recorded dose in the roentgen era was defined, considering the backscatter radiation from the human body. The estimated values of organ-absorbed photon dose per air kerma were almost the same as those in ICRP Publication 116, revealing that the effect of differences in body size was almost negligible. The conversion factors from dosimeter reading to organ-absorbed dose were estimated by period (the roentgen era or from then), nuclear facility type (nuclear power plant or other), dosimeter type, and tissue or organ. The estimated conversion factors ranged from 0.7 to 0.9 (Gy Sv-1). The estimated cumulative organ-absorbed photon dose for the participants of J-EPISODE demonstrated that organ-absorbed dose values were approximately 0.8 times the recorded doses if neglecting dose-unit differences. J-EPISODE reconstructed an organ-absorbed dose conversion factor and will evaluate the risk of cancer mortality and morbidity using the organ-absorbed dose in the future.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.