Evidence map›Paper›PMID 34591463›Full record

ArticleAnalytical chemistry2021

Smartphone-Based Dual-Channel Immunochromatographic Test Strip with Polymer Quantum Dot Labels for Simultaneous Detection of Cypermethrin and 3-Phenoxybenzoic Acid.

Yuting Zhao, Xiaofan Ruan, Yang Song, Jordan N Smith, Natalia Vasylieva, Bruce D Hammock, Yuehe Lin, Dan Du

Abstract read
In one paragraph

Article in Analytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yuting ZhaoSchool of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States.
Xiaofan RuanSchool of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States.
Yang SongSchool of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States.ORCID 0000-0003-0848-4831
Jordan N SmithExposure Science and Pathogen Biology, Pacific Northwest National Laboratory, Richland, Washington 99352, United States.ORCID 0000-0003-3151-2810
Natalia VasylievaDepartment of Entomology and Nematology and UCD Comprehensive Cancer Center, University of California, Davis, Davis, California 95616, United States.
Bruce D HammockDepartment of Entomology and Nematology and UCD Comprehensive Cancer Center, University of California, Davis, Davis, California 95616, United States.ORCID 0000-0003-1408-8317
Yuehe LinSchool of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States.ORCID 0000-0003-3791-7587
Dan DuSchool of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States.ORCID 0000-0003-1952-4042

Funding

Workshop on Environmental Technology Transfer and EntrepreneurshipP42ES004699 · NIEHS · UNIVERSITY OF CALIFORNIA DAVIS · PI HAMMOCK, BRUCE D · 1987 to 2021
$50.1M
Supplement for bioactive lipids as effectors and indicators of the deleterious effects of human healthR35ES030443 · NIEHS · UNIVERSITY OF CALIFORNIA AT DAVIS · PI MORISSEAU, CHRISTOPHE HP · 2019 to 2025
$5.8M
Multiplex Sensor Platform for Biological MonitoringR01OH011023 · OH · BATTELLE PACIFIC NORTHWEST LABORATORIES · PI LIN, YUEHE, SMITH, JORDAN NED · 2016 to 2019
$2.2M
ACL HHS R01OH011023NIEHS NIH HHS P42 ES004699NIEHS NIH HHS R35 ES030443NIOSH CDC HHS R01 OH011023
6 · The paper itself

Abstract

Currently, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-MS (LC-MS) are the primary methods used to detect pesticides and their metabolites for biomonitoring of exposure. Although GC-MS and LC-MS can provide accurate and sensitive measurements, these techniques are not suitable for point-of-care or in-field biomonitoring applications. The objective of this work is to develop a smartphone-based dual-channel immunochromatographic test strip (ICTS) for on-site biomonitoring of exposure to cypermethrin by simultaneous detection of cypermethrin and its metabolite, 3-phenoxybenzoic acid (3-PBA). Polymer carbon dots (PCDs) with ultrahigh fluorescent brightness were synthesized and used as a signal amplifier in ICTS assay. Cypermethrin (a representative pyrethroid pesticide) and its major metabolite 3-PBA were simultaneously detected to provide more comprehensive analysis of cypermethrin exposure. After competitive immunoreactions between the target sample and the coating antigens preloaded on the test line, the tracer antibody (PCD-conjugated antibody) was quantitatively captured on the test lines. The captured PCDs were inversely proportional to the amount of the target compound in the sample. The red fluorescence on the test line was then recorded using a smartphone-based device capable of conducting image analysis and recording. Under optimal conditions, the sensor showed excellent linear responses for detecting cypermethrin and 3-PBA ranging from 1 to 100 ng/mL and from 0.1 to 100 ng/mL, respectively, and the limits of detection were calculated to be ∼0.35 ng/mL for cypermethrin and ∼0.04 ng/mL for 3-PBA. The results demonstrate that the ICTS device is promising for accurate point-of-care biomonitoring of pesticide exposure.

Indexed as

PyrethrinsQuantum DotsBenzoatesPolymersSmartphone3-phenoxybenzoic acidBenzoatescypermethrinPolymersPyrethrins

Identifiers

PMID34591463
PMCPMC8655817

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.