ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2022
Dislocation after reverse total shoulder arthroplasty using contemporary medialized modular systems. Can we still consider it such a frequent complication?
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 12 citations in OpenAlex.
- Refining Reverse Shoulder Arthroplasty: From Implant Design to Patient-Specific Strategy.Journal of clinical medicine · 2026Article
- Functional outcomes and complications of classic grammont-style reverse shoulder arthroplasty in patients with os acromiale: a retrospective case-control study.International orthopaedics · 2025Article
- Intraoperative and early postoperative complications of reverse shoulder arthroplasty: A current concepts review.Journal of orthopaedics · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionImprovement in reverse total shoulder arthroplasty (RTSA) prosthesis and technique has reduced the initially high complication and revision rates associated with this implant. However, instability continues to be a leading cause of reoperation after RTSA, being related in previous studies with medialized designs. The aim of this study was to determine the dislocation rate with the employment of two medialized modular systems of RTSA in our institution. MATERIALS AND
methodsA retrospective review of two different modular systems of RTSA (SMR Modular Shoulder System and Delta XTEND Reverse Shoulder) was performed between 2009 and 2017 with a minimum 3-year follow-up. Baseline demographic, clinical (Constant, ASES and ROM), and radiographic data were collected. Characteristics of postoperative instability cases were also evaluated.
results237 primary RTSA (41% SMR/59% Delta) and 34 revision RTSA (44% SMR/56% Delta) with a mean follow-up of 75.6 ± 5.2 months (79.2 SMR/86.3 Delta, p = .586) were included in the present study. Indications for primary RTSA were osteoarthritis, rotator cuff tear arthropathy and massive irreparable rotator cuff tear (64%), acute fracture (32%), and fracture sequelae (4%). Subscapularis tendon was always repaired in degenerative pathology and tuberosities reattached in traumatic cases. The mean age of the global series was 76.5 ± 5.3 years (75.8 SMR/78.6 Delta, p = .104) with a mean Constant/ASES score at final follow-up of 68.5 ± 4.3/72.9 ± 20.3 (71/68 SMR and 69/74 Delta, p = .653 and .642). Only 2 patients (one acute fracture and one fracture sequelae) suffered an early postoperative anterior dislocation (before 3 months) which represents a rate of .84% in primary cases and .73% including revision surgery. Closed reduction manoeuvres were not successful, and both patients required revision surgery. At the end follow-up, both were stable and had no further dislocations.
conclusionThe dislocation rate after RTSA with the employment of two contemporary modular systems with a medialized centre of rotation is extremely low, especially when compared with the previously published series with the original Grammont design. Acute fracture and fracture sequelae were the main diagnoses associated with this instability. The reasons for the low dislocation rate are multifactorial, but the improvement in the baseplate position according to the more recent standards of "ideal position" and technical aspects such as subscapularis repair or tuberosity reattachment in fractures probably play an important role in this aspect.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.