System introduction and evaluation of the first Chinese chest EIT device for ICU applications.

Shuo-Yao Qu, Meng Dai, Shuo Wu, Zhi-Rang Lv, Xin-Yu Ti, Feng Fu

Abstract readObservational Study
In one paragraph

Observational study in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shuo-Yao Qu *Department of Pulmonary and Critical Care Medicine, Xijing Hospital, Fourth Military Medical University, No. 127 Changle West Road, Xi'an, 710032, China.
Meng Dai *Department of Biomedical Engineering, Fourth Military Medical University, No. 169 Changle West Road, Xincheng District, Xi'an, 710032, China.
Shuo WuDepartment of Pulmonary and Critical Care Medicine, Xijing Hospital, Fourth Military Medical University, No. 127 Changle West Road, Xi'an, 710032, China.
Zhi-Rang LvNorthwest Machine, Xi'an, China.
Xin-Yu TiDepartment of Pulmonary and Critical Care Medicine, Xijing Hospital, Fourth Military Medical University, No. 127 Changle West Road, Xi'an, 710032, China. tixy_pccm@21cn.com.
Feng FuDepartment of Biomedical Engineering, Fourth Military Medical University, No. 169 Changle West Road, Xincheng District, Xi'an, 710032, China. fengfu@fmmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Chest electrical impedance tomography (EIT) is a promising application which is used to monitor the ventilation and perfusion of the lung at the bedside dynamically. The aim of the study was to introduce the first Chinese made chest EIT device for ICU application (Pulmo EIT-100). The system design of the hardware and software was briefly introduced. The performance of the system was compared to PulmoVista 500 (Dräger Medical) in healthy volunteers. The EIT system Pulmo EIT-100 consists of impedance measurement module, power supply module, PC all-in-one machine, medical cart and accessories. The performance of the system current source and voltage measurement unit was tested. A total of 50 healthy lung volunteers were prospectively examined. Subjects were asked to perform repetitive slow vital capacity (SVC) maneuvers with a spirometer. EIT measurements were performed in the following sequence during each SVC with: (1) Pulmo EIT-100, (2) PulmonVista500, (3) Pulmo EIT-100 and (4) PulmonVista500. Linearity and regional ventilation distribution of the reconstructed images from two devices were compared. The output frequency stability of the current source was 2 ppm. The amplitude error within one hour was less than 0.32‰. The output impedance of the current source was about 50kΩ. The signal-to-noise ratio of each measurement channel was ≥ 60 dB. For fixed resistance measurements, the measured values drifted about 0.08% within one hour. For human subjects, the correlations between the spirometry volume and EIT impedance from two devices were both 0.99 ± 0.01. No statistical significances were found in the parameters investigated. The repeatability (variability) of measures from the same device was comparable. Our EIT device delivers reliable data and might be used for patient measurement in a clinical setting.

Indexed as

Intensive Care UnitsPoint-of-Care SystemsAdultChinaElectric ImpedanceFeasibility StudiesFemaleHealthy VolunteersHumansLungMaleMiddle AgedMonitoring, PhysiologicProspective StudiesPulmonary VentilationReproducibility of Results

Identifiers

PMID34588556
PMCPMC8481301

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.