Evidence map›Paper›PMID 34586839›Full record

ArticleScience advances2021

A flexible, stretchable system for simultaneous acoustic energy transfer and communication.

Peng Jin, Ji Fu, Fengle Wang, Yingchao Zhang, Peng Wang, Xin Liu, Yang Jiao, Hangfei Li, Ying Chen, Yinji Ma and 1 more

Abstract read
In one paragraph

Article in Science advances, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 44 papers.

0numbers the graph read from it
0cells of the map it votes in
44citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

44 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Implantable bioelectronic outlet.Science advances · 2026
    Article
  8. Review
  9. Recent advances in transducers for through-tissue ultrasonic power transfer.Progress in biomedical engineering (Bristol, England) · 2026
    Review
  10. Review
  11. Review
  12. Review
  13. Autonomous Implants.Advanced materials (Deerfield Beach, Fla.) · 2025
    Review
  14. Review
  15. Article
  16. Article
  17. Review
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Peng JinAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.ORCID 0000-0002-3537-231X
Ji FuAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
Fengle WangAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.ORCID 0000-0001-5286-9398
Yingchao ZhangAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
Peng WangAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
Xin LiuAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
Yang JiaoAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
Hangfei LiAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
Ying ChenInstitute of Flexible Electronics Technology of THU Jiaxing, Zhejiang 314000, China.
Yinji MaAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
Xue FengAML, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.ORCID 0000-0001-9242-8474

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The use of implantable medical devices, including cardiac pacemakers and brain pacemakers, is becoming increasingly prevalent. However, surgically replacing batteries owing to their limited lifetime is a drawback of those devices. Such an operation poses a risk to patients—a problem that, to date, has not yet been solved. Furthermore, current devices are large and rigid, potentially causing patient discomfort after implantation. To address this problem, we developed a thin, battery-free, flexible, implantable system based on flexible electronic technology that can not only achieve wireless recharging and communication simultaneously via ultrasound but also perform many current device functions, including in vivo physiological monitoring and cardiac pacing. To prove this, an animal experiment was conducted involving creating a cardiac arrest model and powering the system by ultrasound. The results showed that it automatically detected abnormal heartbeats and responded by electrically stimulating the heart, demonstrating the device’s potential clinical utility for emergent treatment.

Identifiers

PMID34586839
PMCPMC8480923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.