ArticleJAMA network open2021
Assessment of the Feasibility of Using Noninvasive Wearable Biometric Monitoring Sensors to Detect Influenza and the Common Cold Before Symptom Onset.
Article in JAMA network open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06161454 (A Feasibility Study of Xofluza Treatment of Influenza in Pediatric Transplant Recipients, Waitlisted Subjects and Household Members After Early Infection Alerting Using Wearable Devices), which is not on this map. Cited by 31 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Feasibility Study of Xofluza Treatment of Influenza in Pediatric Transplant Recipients, Waitlisted Subjects and Household Members After Early Infection Alerting Using Wearable Devices
Who cites it
31 citing papers in PubMed, 50 citations in OpenAlex.
- Characterization of Influenza-Like Illness Burden Using Commercial Wearable Sensor Data and Patient-Reported Outcomes: Mixed Methods Cohort Study.Journal of medical Internet research · 2023Trial
- Population differences in wearable device wear time: Rescuing data to address biases and advance health equity.medRxiv : the preprint server for health sciences · 2026Article
- Influenza virus research in an era of emerging respiratory threats: host-virus interactions, surveillance technologies, antiviral management and resistance, and vaccine preparedness.Frontiers in microbiology · 2026Review
- Innovation in technologies for monitoring lung function in patients with respiratory disease.Breathe (Sheffield, England) · 2025Article
- Article
- Opportunities and Challenges Surrounding the Use of Wearable Sensor Bracelets for Infectious Disease Detection During Hajj: Qualitative Interview Study.JMIR formative research · 2025Article
- Wearable Devices Enable Long COVID Patients to Decrease Symptom Severity: A Case Series From Pilot User Testing.Cardiopulmonary physical therapy journal · 2025Article
- Terminating pandemics with smartwatches.PNAS nexus · 2025Article
- In Vivo Evaluation of Two Hemorrhagic Shock Resuscitation Controllers with Non-Invasive, Intermittent Sensors.Bioengineering (Basel, Switzerland) · 2024Article
- Clinical Interventions Following Escalations from a Continuous Respiratory Monitoring Service in Patients With Chronic Obstructive Pulmonary Disease.Chronic obstructive pulmonary diseases (Miami, Fla.) · 2024Article
- Evaluation of Machine Learning to Detect Influenza Using Wearable Sensor Data and Patient-Reported Symptoms: Cohort Study.Journal of medical Internet research · 2024Observational
- Study of Postacute Sequelae of COVID-19 Using Digital Wearables: Protocol for a Prospective Longitudinal Observational Study.JMIR research protocols · 2024Observational
- Non-invasive ventral cervical magnetoneurography as a proxy of in vivo lipopolysaccharide-induced inflammation.Communications biology · 2024Article
- Changes in behavior and biomarkers during the diagnostic decision period for COVID-19, influenza, and group A streptococcus (GAS): a two-year prospective cohort study in Israel.The Lancet regional health. Europe · 2024Article
- A tree-based explainable AI model for early detection of Covid-19 using physiological data.BMC medical informatics and decision making · 2024Article
- Use of artificial intelligence to develop predictive algorithms of cough and PCR-confirmed COVID-19 infections based on inputs from clinical-grade wearable sensors.Scientific reports · 2024Article
- Remote digital health technologies for improving the care of people with respiratory disorders.The Lancet. Digital health · 2024Review
- Utilizing Wearable Device Data for Syndromic Surveillance: A Fever Detection Approach.Sensors (Basel, Switzerland) · 2024Article
- A prospective natural history study of post acute sequalae of COVID-19 using digital wearables: Study protocol.Research square · 2023Article
- Cardiovascular Autonomic Function and Incident Chronic Obstructive Pulmonary Disease Hospitalizations in Atherosclerosis Risk in Communities.Annals of the American Thoracic Society · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors at 7 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Currently, there are no presymptomatic screening methods to identify individuals infected with a respiratory virus to prevent disease spread and to predict their trajectory for resource allocation. Objective: To evaluate the feasibility of using noninvasive, wrist-worn wearable biometric monitoring sensors to detect presymptomatic viral infection after exposure and predict infection severity in patients exposed to H1N1 influenza or human rhinovirus. Design, Setting, and Participants: The cohort H1N1 viral challenge study was conducted during 2018; data were collected from September 11, 2017, to May 4, 2018. The cohort rhinovirus challenge study was conducted during 2015; data were collected from September 14 to 21, 2015. A total of 39 adult participants were recruited for the H1N1 challenge study, and 24 adult participants were recruited for the rhinovirus challenge study. Exclusion criteria for both challenges included chronic respiratory illness and high levels of serum antibodies. Participants in the H1N1 challenge study were isolated in a clinic for a minimum of 8 days after inoculation. The rhinovirus challenge took place on a college campus, and participants were not isolated. Exposures: Participants in the H1N1 challenge study were inoculated via intranasal drops of diluted influenza A/California/03/09 (H1N1) virus with a mean count of 106 using the median tissue culture infectious dose (TCID50) assay. Participants in the rhinovirus challenge study were inoculated via intranasal drops of diluted human rhinovirus strain type 16 with a count of 100 using the TCID50 assay. Main Outcomes and Measures: The primary outcome measures included cross-validated performance metrics of random forest models to screen for presymptomatic infection and predict infection severity, including accuracy, precision, sensitivity, specificity, F1 score, and area under the receiver operating characteristic curve (AUC). Results: A total of 31 participants with H1N1 (24 men [77.4%]; mean [SD] age, 34.7 [12.3] years) and 18 participants with rhinovirus (11 men [61.1%]; mean [SD] age, 21.7 [3.1] years) were included in the analysis after data preprocessing. Separate H1N1 and rhinovirus detection models, using only data on wearble devices as input, were able to distinguish between infection and noninfection with accuracies of up to 92% for H1N1 (90% precision, 90% sensitivity, 93% specificity, and 90% F1 score, 0.85 [95% CI, 0.70-1.00] AUC) and 88% for rhinovirus (100% precision, 78% sensitivity, 100% specificity, 88% F1 score, and 0.96 [95% CI, 0.85-1.00] AUC). The infection severity prediction model was able to distinguish between mild and moderate infection 24 hours prior to symptom onset with an accuracy of 90% for H1N1 (88% precision, 88% sensitivity, 92% specificity, 88% F1 score, and 0.88 [95% CI, 0.72-1.00] AUC) and 89% for rhinovirus (100% precision, 75% sensitivity, 100% specificity, 86% F1 score, and 0.95 [95% CI, 0.79-1.00] AUC). Conclusions and Relevance: This cohort study suggests that the use of a noninvasive, wrist-worn wearable device to predict an individual's response to viral exposure prior to symptoms is feasible. Harnessing this technology would support early interventions to limit presymptomatic spread of viral respiratory infections, which is timely in the era of COVID-19.