Evidence map›Paper›PMID 34584747›Full record

ArticleHealthcare technology letters2021

Motion artefact removal in electroencephalography and electrocardiography by using multichannel inertial measurement units and adaptive filtering.

Christopher Beach, Mingjie Li, Ertan Balaban, Alexander J Casson

Abstract read
In one paragraph

Article in Healthcare technology letters, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Christopher BeachDepartment of Electrical and Electronic Engineering The University of Manchester Manchester UK.ORCID https://orcid.org/0000-0003-4964-3173
Mingjie LiDesign Engineer, Arm Ltd. Manchester UK.
Ertan BalabanDepartment of Electrical and Electronic Engineering The University of Manchester Manchester UK.ORCID https://orcid.org/0000-0001-7904-6172
Alexander J CassonDepartment of Electrical and Electronic Engineering The University of Manchester Manchester UK.ORCID https://orcid.org/0000-0003-1408-1190

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a new active electrode design for electroencephalogram (EEG) and electrocardiogram (ECG) sensors based on inertial measurement units to remove motion artefacts during signal acquisition. Rather than measuring motion data from a single source for the entire recording unit, inertial measurement units are attached to each individual EEG or ECG electrode to collect local movement data. This data is then used to remove the motion artefact by using normalised least mean square adaptive filtering. Results show that the proposed active electrode design can reduce motion contamination from EEG and ECG signals in chest movement and head swinging motion scenarios. However, it is found that the performance varies, necessitating the need for the algorithm to be paired with more sophisticated signal processing to identify scenarios where it is beneficial in terms of improving signal quality. The new instrumentation hardware allows data driven artefact removal to be performed, providing a new data driven approach compared to widely used blind-source separation methods, and helps enable in the wild EEG recordings to be performed.

Identifiers

PMID34584747
PMCPMC8450177

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked