Evidence map›Paper›PMID 34583738›Full record

ArticleJournal of cardiothoracic surgery2021

The effect of postoperative anticoagulation on false lumen patency after surgery for acute type A aortic dissection.

Mårten Larsson, Gracijela Bozovic, Johan Sjögren, Igor Zindovic, Sigurdur Ragnarsson, Shahab Nozohoor

Abstract read
In one paragraph

Article in Journal of cardiothoracic surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mårten LarssonDepartment of Clinical Sciences Lund, Cardiothoracic Surgery, Lund University and Skåne University Hospital, Getingevägen 4, 221 85, Lund, Sweden. marten.larsson@med.lu.se.ORCID http://orcid.org/0000-0002-2303-2369
Gracijela BozovicDepartment of Medical Imaging and Clinical Physiology, Lund University and Skåne University Hospital, Lund, Sweden.
Johan SjögrenDepartment of Clinical Sciences Lund, Cardiothoracic Surgery, Lund University and Skåne University Hospital, Getingevägen 4, 221 85, Lund, Sweden.
Igor ZindovicDepartment of Clinical Sciences Lund, Cardiothoracic Surgery, Lund University and Skåne University Hospital, Getingevägen 4, 221 85, Lund, Sweden.
Sigurdur RagnarssonDepartment of Clinical Sciences Lund, Cardiothoracic Surgery, Lund University and Skåne University Hospital, Getingevägen 4, 221 85, Lund, Sweden.
Shahab NozohoorDepartment of Clinical Sciences Lund, Cardiothoracic Surgery, Lund University and Skåne University Hospital, Getingevägen 4, 221 85, Lund, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPatent false lumen has been shown to have a negative impact on prognosis after surgery for acute type A aortic dissection (ATAAD). We aimed to assess the effect of postoperative anticoagulation on false lumen patency and clinical outcomes in relation to false lumen status.

methodsPostoperative computed tomographies of 156 patients undergoing ATAAD DeBakey type I surgery were retrospectively evaluated for false lumen patency. The patients were divided into groups determined by anticoagulation treatment at discharge. Uni- and multivariable logistic regression was used for analysing the effect of anticoagulation on the false lumen, and Kaplan-Meier estimates were used to assess the association of a patent false lumen with the incidence of reoperation and long-term survival.

resultsA patent false lumen was present in 81% of the patients. Postoperative anticoagulants were not associated with a patent false lumen (p = 0.48) in univariable analysis. In multivariable analysis, both hemiarch replacement (OR 0.15, CI95% 0.05-0.49, p = 0.001) and the use of betablockers had a protective effect (OR 0.29, CI95% 0.10-0.85, p = 0.023). The Kaplan-Meier estimates for survival and the composite endpoint of survival and freedom from distal reintervention indicated no difference in outcome between patients in regard to anticoagulation treatment (survival p = 0.43, composite p = 0.82) or false lumen status (survival p = 0.21, composite p = 0.09).

conclusionThis study could not show negative effects from the postoperative use of anticoagulants on false lumen status, nor that false lumen patency was associated with poorer prognosis. A hemiarch procedure was shown to be associated with reduced risk of false lumen patency.

Indexed as

Aortic Aneurysm, ThoracicAortic DissectionBlood Vessel Prosthesis ImplantationAcute DiseaseAnticoagulantsHumansRetrospective StudiesRisk FactorsTreatment OutcomeVascular PatencyAnticoagulantsAnticoagulationAortic dissectionFalse lumen

Identifiers

PMID34583738
PMCPMC8480047

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.