ArticleSingapore medical journal2022
Efficacy of SG Shield in reducing droplet contamination during collection of oropharyngeal swab culture specimens.
Article in Singapore medical journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Oropharyngeal swabs for diagnosis of COVID-19 often induce violent coughing, which can disperse infectious droplets onto providers. Incorrectly doffing personal protective equipment (PPE) increases the risk of transmission. A cheap, single-use variation of the face shield invented by a Singaporean team, SG Shield, aims to reduce this risk. This manikin study aimed to study the efficacy of the SG Shield in combination with standard PPE. Methods: A person attired in full PPE whose face and chest was lined with grid paper stood in front of an airway manikin in an enclosed room. A small latex balloon containing ultraviolet fluorescent dye was placed in the oral cavity of the manikin and inflated until explosion to simulate a cough. Three study groups were tested: (a) control (no shield), (b) face shield and (c) SG Shield. The primary outcome was droplet dispersion, determined quantitatively by calculating the proportion of grid paper wall squares stained with fluorescent dye. The secondary outcome was the severity of provider contamination. Results: The SG Shield significantly reduced droplet dispersion to 0% compared to the controls (99.0%, P = 0.001). The face shield also significantly reduced droplet contamination but to a lesser extent (80.0%) compared to the control group (P = 0.001). Although the qualitative severity of droplet contamination was significantly lower in both groups compared to the controls, the face shield group had more contamination of the provider's head and neck. Conclusion: The manikin study showed that the SG Shield significantly reduces droplet dispersion to the swab provider's face and chest.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.