ArticlePolymers2021
Development, Characterization and Valuable Use of Novel Dosimeter Film Based on PVA Polymer Doped Nitro Blue Tetrazolium Dye and AgNO
Article in Polymers, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 9 citations in OpenAlex.
- Article
- Investigation of Colored Film Indicators for the Assessment of the Occasional Radiation Exposure.Gels (Basel, Switzerland) · 2023Article
- Article
- Chemosensing Properties of Coumarin Derivatives: Promising Agents with Diverse Pharmacological Properties, Docking and DFT Investigation.Molecules (Basel, Switzerland) · 2022Article
- Recent Advances in Functional Polymer Materials for Energy, Water, and Biomedical Applications: A Review.Polymers · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
Abstract
Currently, the uncontrolled exposure of individuals to X-rays during medical examinations represents a substantial danger that threatens both medical professionals and patients. Therefore, radiation dosimetry for low X-ray doses is a very important control of radiation practice in medical diagnostic radiology. In line with this, the current study proposes a valuable dosimeter-based PVA thin film doubly doped with silver nitrate salt and nitro blue tetrazolium dye. The nanocomposite film was prepared via a simple casting method and the different processing parameters were optimized. The performance of radiation detection was evaluated according to optical, chromic, chemical and structural changes after exposure to variable low X-ray doses (0, 2, 4, 10 and 20 mGy). The different film labels exhibited an excellent stability behavior in dark and light upon 30 days of storage. The UV-Vis spectrophotometric study showed a gradual increase in the maximum absorbance as a function of the dose and the corresponding response curve confirmed this linear variation (R = 0.998). A clear structural modification was recorded via X-ray diffraction (XRD) analysis revealing the increase in crystallinity with the level of the dose received by the nanocomposite films. Microscopic surface analysis via SEM assessments revealed a significant morphological change in PVA/Ag
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.