ArticleMicromachines2021
Design, Simulation, and Fabrication of a Copper-Chrome-Based Glass Heater Integrated into a PMMA Microfluidic System.
Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
In this paper, the development of a copper-chrome-based glass microheater and its integration into a Polymethylmethacrylate (PMMA) microfluidic system are presented. The process highlights the importance of an appropriate characterization, taking advantage of computer-simulated physical methods in the heat transfer process. The presented system architecture allows the integration for the development of a thermal flow sensor, in which the fluid flows through a 1 mm width × 1 mm length microchannel across a 5 mm width × 13 mm length heating surface. Using an electrothermal analysis, based on a simulation and design process, the surface heating behavior curve was analyzed to choose a heating reference point, primarily used to control the temperature point within the fluidic microsystem. The heater was characterized using the theory of electrical instrumentation, with a 7.22% error for the heating characterization and a 5.42% error for the power consumption, measured at 0.69 W at a temperature of 70 °C. Further tests, at a temperature of 115 °C, were used to observe the effects of the heat transfer through convection on the fluid and the heater surface for different flow rates, which can be used for the development of thermal flowmeters using the configuration presented in this work.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.