Evidence map›Paper›PMID 34577652›Full record

ArticleMicromachines2021

A Kinetic Pump Integrated Microfluidic Plate (KIM-Plate) with High Usability for Cell Culture-Based Multiorgan Microphysiological Systems.

Kenta Shinha, Wataru Nihei, Hiroko Nakamura, Tomomi Goto, Takumi Kawanishi, Naoki Ishida, Nao Yamazaki, Yuki Imakura, Shinji Mima, Kosuke Inamura and 5 more

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 32 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Strategies for modelling endometrial diseases.Nature reviews. Endocrinology · 2022
    Review
  13. Article
  14. Article
  15. Article
  16. Pumped and pumpless microphysiological systems to study (nano)therapeutics.Wiley interdisciplinary reviews. Nanomedicine and nanobiotechnology
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 4 institutions in 1 country.

Kenta ShinhaDepartment of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.
Wataru NiheiDepartment of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.
Hiroko NakamuraDepartment of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.
Tomomi GotoDepartment of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.
Takumi KawanishiFaculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa 920-1192, Japan.
Naoki IshidaFaculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa 920-1192, Japan.
Nao YamazakiBio Science & Engineering Laboratory, FUJIFILM Corporation, 577 Ushijima, Kaisei-machi 258-8577, Japan.
Yuki ImakuraBio Science & Engineering Laboratory, FUJIFILM Corporation, 577 Ushijima, Kaisei-machi 258-8577, Japan.
Shinji MimaBio Science & Engineering Laboratory, FUJIFILM Corporation, 577 Ushijima, Kaisei-machi 258-8577, Japan.
Kosuke InamuraDepartment of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Tokyo 113-8654, Japan.
Hiroshi ArakawaFaculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa 920-1192, Japan.ORCID 0000-0001-6773-7646
Masaki NishikawaDepartment of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Tokyo 113-8654, Japan.
Yukio KatoFaculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa 920-1192, Japan.
Yasuyuki SakaiDepartment of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Tokyo 113-8654, Japan.
Hiroshi KimuraDepartment of Mechanical Engineering, School of Engineering, Tokai University, 4-1-1 Kitakaname, Hiratsuka 259-1292, Japan.ORCID 0000-0003-0623-0248
Tokai University · JPKanazawa University · JPFujifilm (Japan) · JPThe University of Tokyo · JP

Funding

Japan Agency for Medical Research and Development 17be0304201h0001Japan Society for the Promotion of Science 18H01849
6 · The paper itself

Abstract

Microphysiological systems (MPSs), including organ-on-a-chip (OoC), have attracted attention as a novel method for estimating the effects and side effects of drugs in drug discovery. To reproduce the dynamic in vivo environment, previous MPSs were connected to pump systems to perfuse culture medium. Therefore, most MPSs are not user-friendly and have poor throughput. We aimed to develop a kinetic pump integrated microfluidic plate (KIM-Plate) by applying the stirrer-based micropump to an open access culture plate to improve the usability of MPSs. The KIM-Plate integrates six multiorgan MPS (MO-MPS) units and meets the ANSI/SBS microplate standards. We evaluated the perfusion function of the kinetic pump and found that the KIM-Plate had sufficient agitation effect. Coculture experiments with PXB cells and hiPS intestinal cells showed that the TEER of hiPS intestinal cells and gene expression levels related to the metabolism of PXB cells were increased. Hence, the KIM-Plate is an innovative tool for the easy coculture of highly conditioned cells that is expected to facilitate cell-based assays in the fields of drug discovery and biology because of its usability and high throughput nature.

Indexed as

cell-based assaycoculturekinetic pumpmicrophysiological system (MPS)organ-on-a-chip

Identifiers

PMID34577652
PMCPMC8471412
OpenAlexW3194565741

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.