ArticleSensors (Basel, Switzerland)2021
Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors.
Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 19 citations in OpenAlex.
- Feasibility of low-cost particle sensor types in long-term indoor air pollution health studies after repeated calibration, 2019-2021.Scientific reports · 2022Article
- Energy-Efficient Monitoring of Fine Particulate Matter with Tiny Aerosol Conditioner.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
Abstract
Air pollution is a social problem, because the harmful suspended materials can cause diseases and deaths to humans. Specifically, particulate matters (PM), a form of air pollution, can contribute to cardiovascular morbidity and lung diseases. Nowadays, humans are exposed to PM pollution everywhere because it occurs in both indoor and outdoor environments. To purify or ventilate polluted air, one need to accurately monitor the ambient air quality. Therefore, this study proposed a practical particulate matter sensing and accurate calibration system using low-cost commercial sensors. The proposed system basically uses noisy and inaccurate PM sensors to measure the ambient air pollution. This paper mainly deals with three types of error caused in the light scattering method: short-term noise, part-to-part variation, and temperature and humidity interferences. We propose a simple short-term noise reduction method to correct measurement errors, an auto-fitting calibration for part-to-part repeatability to pinpoint the baseline of the signal that affects the performance of the system, and a temperature and humidity compensation method. This paper also contains the experiment setup and performance evaluation to prove the superiority of the proposed methods. Based on the evaluation of the performance of the proposed system, part-to-part repeatability was less than 2 μg/m
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.