Evidence map›Paper›PMID 34577222›Full record

ArticleSensors (Basel, Switzerland)2021

Identification of Ictal Tachycardia in Focal Motor- and Non-Motor Seizures by Means of a Wearable PPG Sensor.

Martin Glasstetter, Sebastian Böttcher, Nicolas Zabler, Nino Epitashvili, Matthias Dümpelmann, Mark P Richardson, Andreas Schulze-Bonhage

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 20 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Seizure Detection Devices.Journal of clinical medicine · 2025
    Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Martin GlasstetterEpilepsy Center, Department of Neurosurgery, Medical Center-University of Freiburg, 79106 Freiburg im Breisgau, Germany.ORCID 0000-0002-4929-4332
Sebastian BöttcherEpilepsy Center, Department of Neurosurgery, Medical Center-University of Freiburg, 79106 Freiburg im Breisgau, Germany.ORCID 0000-0002-3407-8290
Nicolas ZablerEpilepsy Center, Department of Neurosurgery, Medical Center-University of Freiburg, 79106 Freiburg im Breisgau, Germany.ORCID 0000-0002-4406-1863
Nino EpitashviliEpilepsy Center, Department of Neurosurgery, Medical Center-University of Freiburg, 79106 Freiburg im Breisgau, Germany.ORCID 0000-0003-2765-8286
Matthias DümpelmannEpilepsy Center, Department of Neurosurgery, Medical Center-University of Freiburg, 79106 Freiburg im Breisgau, Germany.ORCID 0000-0002-1476-7777
Mark P RichardsonDivision of Neuroscience, Institute of Psychiatry, Psychology & Neuroscience King's College London, London SE5 9RT, UK.ORCID 0000-0001-8925-3140
Andreas Schulze-BonhageEpilepsy Center, Department of Neurosurgery, Medical Center-University of Freiburg, 79106 Freiburg im Breisgau, Germany.ORCID 0000-0003-2382-0506
University of Freiburg · DEKing's College London · GB

Funding

Innovative Medicines Initiative 115902
6 · The paper itself

Abstract

Photoplethysmography (PPG) as an additional biosignal for a seizure detector has been underutilized so far, which is possibly due to its susceptibility to motion artifacts. We investigated 62 focal seizures from 28 patients with electrocardiography-based evidence of ictal tachycardia (IT). Seizures were divided into subgroups: those without epileptic movements and those with epileptic movements not affecting and affecting the extremities. PPG-based heart rate (HR) derived from a wrist-worn device was calculated for sections with high signal quality, which were identified using spectral entropy. Overall, IT based on PPG was identified in 37 of 62 (60%) seizures (9/19, 7/8, and 21/35 in the three groups, respectively) and could be found prior to the onset of epileptic movements affecting the extremities in 14/21 seizures. In 30/37 seizures, PPG-based IT was in good temporal agreement (<10 s) with ECG-based IT, with an average delay of 5.0 s relative to EEG onset. In summary, we observed that the identification of IT by means of a wearable PPG sensor is possible not only for non-motor seizures but also in motor seizures, which is due to the early manifestation of IT in a relevant subset of focal seizures. However, both spontaneous and epileptic movements can impair PPG-based seizure detection.

Indexed as

PhotoplethysmographyWearable Electronic DevicesElectrocardiographyElectroencephalographyHeart RateHumansSeizuresSignal Processing, Computer-AssistedTachycardiaheart rateictal tachycardiamotor and non-motor seizuresphotoplethysmography (PPG)signal qualitywearable device

Identifiers

PMID34577222
PMCPMC8470979
OpenAlexW3196706059

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.