Evidence map›Paper›PMID 34573994›Full record

ArticleDiagnostics (Basel, Switzerland)2021

Development of an Electronic Portal Imaging Device Dosimetry Method.

Jun Zhang, Ziting Fan, Xile Zhang, Ruijie Yang, Junhai Wen

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jun ZhangDepartment of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.ORCID 0000-0002-9496-9845
Ziting FanDepartment of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.
Xile ZhangDepartment of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China.
Ruijie YangDepartment of Radiation Oncology, Peking University Third Hospital, Beijing 100191, China.ORCID 0000-0002-3459-0075
Junhai WenDepartment of Biomedical Engineering, School of Life Science, Beijing Institute of Technology, Beijing 100081, China.

Funding

Beijing Municipal Commission of science and technology collaborative innovation project Z201100005620012Capital's Funds for Health Improvement and Research 2020-2Z-40919National Key Research and Development Program of China 2016YFC0105104National Natural Science Foundation of China No. U1830126
6 · The paper itself

Abstract

Support arm backscatter and off-axis effects of an electronic portal imaging device (EPID) are challenging for radiotherapy quality assurance. Aiming at the issue, we proposed a simple yet effective method with correction matrices to rectify backscatter and off-axis responses for EPID images. First, we measured the square fields with ionization chamber array (ICA) and EPID simultaneously. Second, we calculated the dose-to-pixel value ratio and used it as the correction matrix of the corresponding field. Third, the correction value of the large field was replaced with that of the same point in the small field to generate a correction matrix suitable for different EPID images. Finally, we rectified the EPID image with the correction matrix, and then the processed EPID images were converted into the absolute dose. The calculated dose was compared with the measured dose via ICA. The gamma pass rates of 3%/3 mm and 2%/2 mm (5% threshold) were 99.6% ± 0.94% and 95.48% ± 1.03%, and the average gamma values were 0.28 ± 0.04 and 0.42 ± 0.05, respectively. Experimental results verified our method accurately corrected EPID images and converted pixel values into absolute dose values such that EPID was an efficient radiotherapy dosimetry tool.

Indexed as

backscatterEPIDoff-axisportal dosimetryquality assuranceradiotherapy

Identifiers

PMID34573994
PMCPMC8464714

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.