Dual-energy CT imaging over non-overlapping, orthogonal arcs of limited-angular ranges.

Buxin Chen, Zheng Zhang, Dan Xia, Emil Y Sidky, Xiaochuan Pan

Abstract read
In one paragraph

Article in Journal of X-ray science and technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Directional TV algorithm for fast EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2024
    Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Buxin ChenDepartment of Radiology, The University of Chicago, Chicago, IL, USA.
Zheng ZhangDepartment of Radiology, The University of Chicago, Chicago, IL, USA.
Dan XiaDepartment of Radiology, The University of Chicago, Chicago, IL, USA.
Emil Y SidkyDepartment of Radiology, The University of Chicago, Chicago, IL, USA.
Xiaochuan PanDepartment of Radiology, The University of Chicago, Chicago, IL, USA.

Funding

Advanced iterative image reconstruction for digital breast tomosynthesis - Resubmission 01R01EB026282 · NIBIB · UNIVERSITY OF CHICAGO · PI PAN, XIAOCHUAN, SIDKY, EMIL Y · 2018 to 2021
$2.1M
Spectral CT metal artifact correctionR01EB023968 · NIBIB · MARQUETTE UNIVERSITY · PI SCHMIDT, TALY GILAT, SIDKY, EMIL Y · 2019 to 2022
$1.4M
Algorithm-Enabled Auto-Calibrating Quantitative Dual-Energy CTR21CA263660 · NCI · UNIVERSITY OF CHICAGO · PI PAN, XIAOCHUAN · 2022 to 2023
$414k
NCI NIH HHS R21 CA263660NIBIB NIH HHS R01 EB023968NIBIB NIH HHS R01 EB026282
6 · The paper itself

Abstract

backgroundInterest exists in dual-energy computed tomography (DECT) imaging with scanning arcs of limited-angular ranges (LARs) for reducing scan time and radiation dose, and for enabling scan configurations of C-arm CT that can avoid possible collision between the rotating X-ray tube/detector and the imaged subject.

objectiveIn this work, we investigate image reconstruction for a type of configurations of practical DECT interest, referred to as the two-orthogonal-arc configuration, in which low- and high-kVp data are collected over two non-overlapping arcs of equal LAR α, ranging from 30° to 90°, separated by 90°. The configuration can readily be implemented, e.g., on CT with dual sources separated by 90° or with the slow-kVp-switching technique.

methodsThe directional-total-variation (DTV) algorithm developed previously for image reconstruction in conventional, single-energy CT is tailored to enable image reconstruction in DECT with two-orthogonal-arc configurations.

resultsPerforming visual inspection and quantitative analysis of monochromatic images obtained and effective atomic numbers estimated, we observe that the monochromatic images of the DTV algorithm from LAR data are with substantially reduced LAR artifacts, which are observed otherwise in those of existing algorithms, and thus visually correlate reasonably well, in terms of metrics PCC and nMI, with their reference images obtained from full-angular-range data. In addition, effective atomic numbers estimated from LAR data of DECT with two-orthogonal-arc configurations are in reasonable agreement, with relative errors up to ∼  10%, with those estimated from full-angular-range data in DECT.

conclusionsThe results acquired in the work may yield insights into the design of LAR configurations of practical dual-energy application relevance in diagnostic CT or C-arm CT imaging.

Indexed as

Image Processing, Computer-AssistedTomography, X-Ray ComputedAlgorithmsArtifactsPhantoms, ImagingDECTdirectional total variationlimited-angular rangetwo-orthogonal-arc