Evidence map›Paper›PMID 34567683›Full record

ReviewMicrosystems & nanoengineering2020

Capacitive micromachined ultrasound transducers for intravascular ultrasound imaging.

Jiaqi Wang, Zhou Zheng, Jasmine Chan, John T W Yeow

Open access · goldAbstract readReview
In one paragraph

Review in Microsystems & nanoengineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers.

0numbers the graph read from it
0cells of the map it votes in
35citing papers in PubMed
3.8field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

35 citing papers in PubMed, 101 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Analog interface amplifiers for sub-mm broadband polymer intravascular ultrasonic imaging.IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Jiaqi WangDepartment of Systems Design Engineering, Faculty of Engineering, University of Waterloo, Waterloo, ON N2L 3G1 Canada.ORCID 0000-0002-9540-1207
Zhou ZhengDepartment of Systems Design Engineering, Faculty of Engineering, University of Waterloo, Waterloo, ON N2L 3G1 Canada.
Jasmine ChanDepartment of Systems Design Engineering, Faculty of Engineering, University of Waterloo, Waterloo, ON N2L 3G1 Canada.
John T W YeowDepartment of Systems Design Engineering, Faculty of Engineering, University of Waterloo, Waterloo, ON N2L 3G1 Canada.
University of Waterloo · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intravascular ultrasound (IVUS) is a burgeoning imaging technology that provides vital information for the diagnosis of coronary arterial diseases. A significant constituent that enables the IVUS system to attain high-resolution images is the ultrasound transducer, which acts as both a transmitter that sends acoustic waves and a detector that receives the returning signals. Being the most mature form of ultrasound transducer available in the market, piezoelectric transducers have dominated the field of biomedical imaging. However, there are some drawbacks associated with using the traditional piezoelectric ultrasound transducers such as difficulties in the fabrication of high-density arrays, which would aid in the acceleration of the imaging speed and alleviate motion artifact. The advent of microelectromechanical system (MEMS) technology has brought about the development of micromachined ultrasound transducers that would help to address this issue. Apart from the advantage of being able to be fabricated into arrays with lesser complications, the image quality of IVUS can be further enhanced with the easy integration of micromachined ultrasound transducers with complementary metal-oxide-semiconductor (CMOS). This would aid in the mitigation of parasitic capacitance, thereby improving the signal-to-noise. Currently, there are two commonly investigated micromachined ultrasound transducers, piezoelectric micromachined ultrasound transducers (PMUTs) and capacitive micromachined ultrasound transducers (CMUTs). Currently, PMUTs face a significant challenge where the fabricated PMUTs do not function as per their design. Thus, CMUTs with different array configurations have been developed for IVUS. In this paper, the different ultrasound transducers, including conventional-piezoelectric transducers, PMUTs and CMUTs, are reviewed, and a summary of the recent progress of CMUTs for IVUS is presented.

Indexed as

Electrical and electronic engineeringEngineering

Identifiers

PMID34567683
PMCPMC8433336
OpenAlexW3080789511

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.