Evidence map›Paper›PMID 34567665›Full record

ArticleMicrosystems & nanoengineering2020

Development and optimization of thermal contrast amplification lateral flow immunoassays for ultrasensitive HIV p24 protein detection.

Li Zhan, Timothy Granade, Yilin Liu, Xierong Wei, Ae Youngpairoj, Vickie Sullivan, Jeff Johnson, John Bischof

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Li ZhanDepartment of Mechanical Engineering, University of Minnesota, Minneapolis, MN USA.
Timothy GranadeCenters for Disease Control and Prevention, Atlanta, GA USA.
Yilin LiuDepartment of Mechanical Engineering, University of Minnesota, Minneapolis, MN USA.
Xierong WeiCenters for Disease Control and Prevention, Atlanta, GA USA.
Ae YoungpairojCenters for Disease Control and Prevention, Atlanta, GA USA.
Vickie SullivanCenters for Disease Control and Prevention, Atlanta, GA USA.
Jeff JohnsonCenters for Disease Control and Prevention, Atlanta, GA USA.
John BischofDepartment of Mechanical Engineering, University of Minnesota, Minneapolis, MN USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Detection of human immunodeficiency virus (HIV) p24 protein at a single pg/ml concentration in point-of-care (POC) settings is important because it can facilitate acute HIV infection diagnosis with a detection sensitivity approaching that of laboratory-based assays. However, the limit of detection (LOD) of lateral flow immunoassays (LFAs), the most prominent POC diagnostic platform, falls short of that of laboratory protein detection methods such as enzyme-linked immunosorbent assay (ELISA). Here, we report the development and optimization of a thermal contrast amplification (TCA) LFA that will allow ultrasensitive detection of 8 pg/ml p24 protein spiked into human serum at POC, approaching the LOD of a laboratory test. To achieve this aim, we pursued several innovations as follows: (a) defining a new quantitative figure of merit for LFA design based on the specific to nonspecific binding ratio (BR); (b) using different sizes and shapes of gold nanoparticles (GNPs) in the systematic optimization of TCA LFA designs; and (c) exploring new laser wavelengths and power regimes for TCA LFA designs. First, we optimized the blocking buffer for the membrane and running buffer by quantitatively measuring the BR using a TCA reader. The TCA reader interprets the thermal signal (i.e., temperature) of GNPs within the membrane when irradiated by a laser at the plasmon resonance wavelength of the particle. This process results in higher detection and quantitation of GNPs than in traditional visual detection (i.e., color intensity). Further, we investigated the effect of laser power (30, 100, 200 mW), GNP size and shape (30 and 100 nm gold spheres, 150 nm gold-silica shells), and laser wavelength (532, 800 nm). Applying these innovations to a new TCA LFA design, we demonstrated that 100 nm spheres with a 100 mW 532 nm laser provided the best performance (i.e., LOD = 8 pg/ml). This LOD is significantly better than that of the current colorimetric LFA and is in the range of the laboratory-based p24 ELISA. In summary, this TCA LFA for p24 protein shows promise for detecting acute HIV infection in POC settings.

Indexed as

BiosensorsNanoparticles

Identifiers

PMID34567665
PMCPMC8433161

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.