Evidence map›Paper›PMID 34567612›Full record

ArticleJournal of rehabilitation and assistive technologies engineering

A self-aligning end-effector robot for individual joint training of the human arm.

Sivakumar Balasubramanian, Sandeep Guguloth, Javeed Shaikh Mohammed, S Sujatha

Abstract read
In one paragraph

Article in Journal of rehabilitation and assistive technologies engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sivakumar BalasubramanianDepartment of Bioengineering, Christian Medical College, Vellore, India.ORCID https://orcid.org/0000-0001-5915-1346
Sandeep GugulothDepartment of Mechanical Engineering, Indian Institute of Technology - Madras, Chennai, India.
Javeed Shaikh MohammedDepartment of Mechanical Engineering, Indian Institute of Technology - Madras, Chennai, India.ORCID https://orcid.org/0000-0001-9079-3101
S SujathaDepartment of Mechanical Engineering, Indian Institute of Technology - Madras, Chennai, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimIntense training of arm movements using robotic devices can help reduce impairments in stroke. Recent evidence indicates that independent training of individual joints of the arm with robots can be as effective as coordinated multi-joint arm training. This makes a case for designing and developing robots made for training individual joints, which can be simpler and more compact than the ones for coordinate multi-joint arm training. The design of such a robot is the aim of the work presented in this paper.

methodsAn end-effector robot kinematic design was developed and the optimal robot link lengths were estimated using an optimization procedure. A simple algorithm for automatically detecting human limb parameters is proposed and its performance was evaluated through a simulation study.

resultsA six-degrees-of-freedom end-effector robot with three actuated degrees-of-freedom and three non-actuated self-aligning degrees-of-freedom for safe assisted training of the individual joints (shoulder or elbow) of the human arm was conceived. The proposed robot has relaxed constraints on the relative positioning of the human limb with respect to the robot. The optimized link lengths chosen for the robot allow it to cover about 80% of the human limb's workspace, and possess good overall manipulability. The simple estimation procedure was demonstrated to estimate human limb parameters with low bias and variance. DISCUSSION: The proposed robot with three actuated and three non-actuated degrees-of-freedom has a compact structure suitable for both the left and right arms without any change to its structure. The proposed automatic estimation procedure allows the robot to safely apply forces and impose movements to the human limb, without the need for any manual measurements. Such compact robots have the highest potential for clinical translation.

Indexed as

Armmechanismsrehabilitationroboticsself-aligning

Identifiers

PMID34567612
PMCPMC8459188

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked