Evidence map›Paper›PMID 34566563›Full record

ArticleFrontiers in neuroscience2021

The Role of Electrode-Site Placement in the Long-Term Stability of Intracortical Microstimulation.

Ramya L Saldanha, Morgan E Urdaneta, Kevin J Otto

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.5field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Stability Assessment of Ultramicroelectrode Arrays in Neural Stimulation: an Electrochemical Impedance Spectroscopy Analysis.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Ramya L SaldanhaJ. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States.
Morgan E UrdanetaDepartment of Neuroscience, University of Florida, Gainesville, FL, United States.
Kevin J OttoJ. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States.
University of Florida · US

Funding

Micro-coil implants for cortical activationU01NS099700 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI FRIED, SHELLEY · 2016 to 2018
$2.9M
NINDS NIH HHS U01 NS099700
6 · The paper itself

Abstract

Intracortical microelectrodes are neuroprosthetic devices used in brain-machine interfaces to both record and stimulate neural activity in the brain. These technologies have been improved by advances in microfabrication, which have led to the creation of subcellular and high-density microelectrodes. The greater number of independent stimulation channels in these devices allows for improved neuromodulation selectivity, compared to single-site microelectrodes. Elements of electrode design such as electrode-site placement can influence the long-term performance of neuroprostheses. Previous studies have shown that electrode-sites placed on the edge of a planar microelectrode have greater chronic recording functionality than sites placed in the center. However, the effect of electrode-site placement on long-term intracortical microstimulation (ICMS) is still unknown. Here, we show that, in rats chronically implanted with custom-made planar silicon microelectrodes, electrode-sites on the tip of the device outperformed those on both the edge and center in terms of the effect per charge delivered, though there is still a slight advantage to using edge sites over center sites for ICMS. Longitudinal analysis of ICMS detection thresholds over a 16-week period revealed that while all sites followed a similar trend over time, the tip and edge sites consistently elicited the behavioral response with less charge compared to center sites. Furthermore, we quantified channel activity over time and found that edge sites remained more active than center sites over time, though the rate of decay of active sites for center and edge sites was comparable. Our results demonstrate that electrode-site placement plays an important role in the long-term stability of intracortical microstimulation and could be a potential factor to consider in the design of future intracortical electrodes.

Indexed as

brain-machine interfaceselectrode designintracortical microelectrodesmicrostimulationneuroprosthetics

Identifiers

PMID34566563
PMCPMC8455844
OpenAlexW3198869331

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.