Evidence map›Paper›PMID 34564201›Full record

ArticleJournal of functional biomaterials2021

In Vitro Corrosion of SiC-Coated Anodized Ti Nano-Tubular Surfaces.

Shu-Min Hsu, Chaker Fares, Xinyi Xia, Md Abu Jafar Rasel, Jacob Ketter, Samira Esteves Afonso Camargo, Md Amanul Haque, Fan Ren, Josephine F Esquivel-Upshaw

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Shu-Min HsuDepartment of Restorative Dental Sciences, Division of Prosthodontics, University of Florida College of Dentistry, Gainesville, FL 32610, USA.ORCID 0000-0003-0701-0896
Chaker FaresDepartment of Chemical Engineering, University of Florida, Gainesville, FL 32610, USA.ORCID 0000-0001-9596-2381
Xinyi XiaDepartment of Chemical Engineering, University of Florida, Gainesville, FL 32610, USA.
Md Abu Jafar RaselDepartment of Mechanical Engineering, Penn State University, University Park, PA 16802, USA.
Jacob KetterGamry Instruments, Warminster, PA 18974, USA.
Samira Esteves Afonso CamargoDepartment of Restorative Dental Sciences, Division of Prosthodontics, University of Florida College of Dentistry, Gainesville, FL 32610, USA.
Md Amanul HaqueDepartment of Mechanical Engineering, Penn State University, University Park, PA 16802, USA.
Fan RenDepartment of Chemical Engineering, University of Florida, Gainesville, FL 32610, USA.ORCID 0000-0001-9234-019X
Josephine F Esquivel-UpshawDepartment of Restorative Dental Sciences, Division of Prosthodontics, University of Florida College of Dentistry, Gainesville, FL 32610, USA.ORCID 0000-0003-3642-8087

Funding

Novel coatings to minimize surface degradation and fracture susceptibility of dental ceramicsR01DE025001 · NIDCR · UNIVERSITY OF FLORIDA · PI ESQUIVEL-UPSHAW, JOSEPHINE F. · 2016 to 2020
$4.2M
NIDCR NIH HHS R01 DE025001
6 · The paper itself

Abstract

Peri-implantitis leads to implant failure and decreases long-term survival and success rates of implant-supported prostheses. The pathogenesis of this disease is complex but implant corrosion is believed to be one of the many factors which contributes to progression of this disease. A nanostructured titanium dioxide layer was introduced using anodization to improve the functionality of dental implants. In the present study, we evaluated the corrosion performance of silicon carbide (SiC) on anodized titanium dioxide nanotubes (ATO) using plasma-enhanced chemical vapor deposition (PECVD). This was investigated through a potentiodynamic polarization test and bacterial incubation for 30 days. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to analyze surface morphologies of non-coated and SiC-coated nanotubes. Energy dispersive X-ray (EDX) was used to analyze the surface composition. In conclusion, SiC-coated ATO exhibited improved corrosion resistance and holds promise as an implant coating material.

Indexed as

corrosionperi-implantitissurface modificationtitanium implant

Identifiers

PMID34564201
PMCPMC8482235

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.