Evidence map›Paper›PMID 34562918›Full record

ArticleBiosensors2021

A Vascular Intervention Assist Device Using Bi-Motional Roller Cartridge Structure and Clinical Evaluation.

Jueun Choi, Sangeun Park, Young-Hak Kim, Youngjin Moon, Jaesoon Choi

Open access · goldAbstract read
In one paragraph

Article in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 21 citations in OpenAlex.

  1. Review
  2. Novel Design of a Surgical Tool Insertion Robot Using a Chebyshev Lambda Mechanism.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  3. A Master-Follower Teleoperation System for Robotic Catheterisation: Design, Characterisation and Tracking Control.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  4. Review
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jueun ChoiDepartment of Biomedical Engineering, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea.ORCID 0000-0003-3860-3635
Sangeun ParkBiomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul 05505, Korea.
Young-Hak KimDepartment of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea.
Youngjin MoonBiomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul 05505, Korea.ORCID 0000-0002-8573-1149
Jaesoon ChoiDepartment of Biomedical Engineering, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea.ORCID 0000-0002-6817-618X
Ulsan College · KRAsan Medical Center · KR

Funding

Korea Health Industry Development Institute 20001638Ministry of Health and Welfare H17C2410
6 · The paper itself

Abstract

Conventional vascular intervention procedures present issues including X-ray exposure during operation, and an experience-dependent success rate and clinical outcome. This paper presents a novel robotic system using modularized bi-motional roller cartridge assemblies for robotic vascular interventions, specifically percutaneous coronary interventions (PCIs). The patient-side robot manipulates instruments such as the guiding catheter, guidewire, balloon/stent catheter, and diagnostic sensor catheter via commands from the user interface device, which is controlled by the physician. The proposed roller cartridge assembly can accommodate instruments of various sizes with an active clamping mechanism, and implements simultaneous translation and rotation motions. It also implements force feedback in the physician-side system, to effectively monitor the patient-side system's status. The positioning accuracy and precision in using the robotic system showed satisfactory performance in a phantom-based test. It was also confirmed, through animal experiments and a pilot clinical trial, that the system demonstrates feasibility for clinical use.

Indexed as

Equipment DesignCatheterizationFeedbackHumansMechanical PhenomenaMotionRobotic Surgical Procedurescardiovascular interventionguidewiremaster–slave systemmedical robotteleoperation control

Identifiers

PMID34562918
PMCPMC8472030
OpenAlexW3201293534

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked