ArticleJournal of clinical monitoring and computing2022
VACuum INtubation (VACcIN) box restricts the exhaled air dispersion generated by simulated cough: description and simulation-based tests of an innovative aerosolization protective prototype.
Article in Journal of clinical monitoring and computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Aerosol Box Use in Reducing Health Care Worker Contamination During Airway Procedures (AIRWAY Study): A Simulation-Based Randomized Clinical Trial.JAMA network open · 2023Trial
- A Portable, Foldable Negative-Pressure Aerosol-Containment System (FNPACS) for Aerosol Control During Aerosol-Generating Procedures.Bioengineering (Basel, Switzerland) · 2026Article
- Efficiency, limitations, and familiarization of a novel negative pressure aerosol box for intubation: a simulation-based randomized crossover study.Clinical and experimental emergency medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The COVID-19 pandemic has caused personal protective equipment shortages worldwide and required healthcare workers to develop novel ways of protecting themselves. Anesthesiologists in particular are exposed to increased risks of contamination when performing interventions such as airway manipulations. We developed and tested an aerosolization protective device which contains aerosols around the patient's airway and helps eliminate particles using negative pressure. This intubation box is a polymethyl methacrylate prism with openings for gloves, integrated suction and ventilation connectors. We conducted a randomised controlled series of tests to detect 0.5 µm particles after a simulated cough inside the intubation box, using a high-fidelity simulation mannequin. Setting and main outcome: We measured particle concentrations inside the box with and without suction turned on, in both negative and positive pressure operating rooms. We also obtained particle concentrations outside our box and compared them to non-airtight barrier devices. One minute following simulated cough, the mean number of particles per cubic foot in our box with suction on is around 45% that with the suction off (1,462,373 vs 3,272,080, P < 0.0001) in the negative pressure room, and four times lower than with the suction off (760,380 vs 3,088,700, P < 0.0001) in the positive pressure room. After a simulated cough inside the box, particles can be detected in front of the anesthesiologist's face with a non-airtight device, while none are detected when our box is sealed and its suction turned on. The use of our negative pressure intubation box prevents contamination of surroundings and increases particle elimination, regardless of room pressure.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.