ArticleJournal of clinical monitoring and computing2022
Clinical evaluation of a cutaneous zero-heat-flux thermometer during cardiac surgery.
Article in Journal of clinical monitoring and computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- A prospective randomized study of the efficacy of continuous active warming in patients undergoing laparoscopic gastrectomy.BMC gastroenterology · 2025Trial
- Clinical agreement and physiological relevance of the zero-heat-flux temperature measurement in trauma patients during operating room resuscitation.Journal of clinical monitoring and computing · 2026Observational
- Zero-heat flux skin temperature tracks nasopharyngeal temperature during cardiac surgery with cardiopulmonary bypass: a prospective observational study.BMC anesthesiology · 2026Observational
- Agreement of zero-heat-flux thermometry compared with infrared tympanic temperature monitoring in adults undergoing major surgery.European journal of medical research · 2025Observational
- Agreement between three noninvasive temperature monitoring devices during spinal anaesthesia for caesarean delivery: a prospective observational study.Journal of clinical monitoring and computing · 2024Observational
- Accuracy of a zero-heat-flux thermometer in cardiac surgery, a prospective, multicentre, method comparison study.Scientific reports · 2024Observational
- Agreement of zero-heat-flux thermometry with the oesophageal and tympanic core temperature measurement in patient receiving major surgery.Journal of clinical monitoring and computing · 2024Article
- Accuracy of non-invasive sensors measuring core body temperature in cardiac surgery ICU patients - results from a monocentric prospective observational study.Journal of clinical monitoring and computing · 2023Observational
- Measurement of exhaled breath temperature in patients under general anesthesia: A feasibility study.Biomedical reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We evaluated the disposable non-invasive SpotOn™ thermometer relying on the zero-heat-flux technology. We tested the hypothesis that this technology may accurately estimate the core temperature. The primary objective was to compare cutaneous temperature measurements from this device with blood temperatures measured with the pulmonary artery catheter. Secondary objective was to compare measurements from the zero-heat-flux thermometer indirectly with other routinely used thermometers (nasopharyngeal, bladder, rectal). We included 40 patients electively scheduled for either off-pump coronary artery bypass surgery or pulmonary thromboendarterectomy. Temperatures were measured using zero-heat-flux (SpotOn™), pulmonary artery catheter, nasopharyngeal, rectal, and bladder thermometers. Agreement was assessed using the Bland and Altman random effects method for repeated measures data, and Lin's concordance correlation coefficient. Accuracy was estimated (defined as <0.5° difference with the gold standard), with a 95% confidence interval considering the multiple pairs of measurements per patient. 17 850 sets of temperature measurements were analyzed from 40 patients. The mean overall difference between zero-heat-flux and pulmonary artery catheter thermometer was -0.06 °C (95% limits of agreement of ± 0.89 °C). In addition, 14 968 sets of temperature measurements were analyzed from 34 patients with all thermometers in situ. Results from the zero-heat-flux thermometer showed better agreement with the pulmonary artery catheter than the other secondary core thermometers assessed. In conclusion, the SpotOn™ thermometer reliably assessed core temperature during cardiac surgery. It could be considered an alternative for other secondary thermometers in the assessment of core temperature during general anesthesia.
Indexed as
Identifiers
34559326What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.