ArticleScientific reports2021
Minimally-invasive insertion strategy and in vivo evaluation of multi-shank flexible intracortical probes.
Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Repeatable, low-drift recordings in behaving nonhuman primates using flexible microelectrodes.Nature communications · 2026Article
- Fabrication of High-Density Multimodal Neural Probes Based on Heterogeneously Integrated CMOS.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Systematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods.Journal of neural engineering · 2026Article
- Repeatable, low-drift recordings in behaving non-human primates using flexible microelectrodes.bioRxiv : the preprint server for biology · 2026Article
- Flexible 3D Kirigami Probes for In Vitro and In Vivo Neural Applications.Advanced materials (Deerfield Beach, Fla.) · 2025Article
- Designing Multifunctional Microneedles in Biomedical Engineering: Materials, Methods, and Applications.International journal of nanomedicine · 2025Review
- High-Density, Conformable Conducting Polymer-Based Implantable Neural Probes for the Developing Brain.Advanced healthcare materials · 2024Article
- Multilayer Arrays for Neurotechnology Applications (MANTA): Chronically Stable Thin-Film Intracortical Implants.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023Article
- Physical behavior of PEDOT polymer electrode during magnetic resonance imaging and long-term test in the climate chamber.Scientific reports · 2023Article
- Electrophysiological properties of layer 2/3 pyramidal neurons in the primary visual cortex of a retinitis pigmentosa mouse model (Frontiers in cellular neuroscience · 2023Article
- Advancing the interfacing performances of chronically implantable neural probes in the era of CMOS neuroelectronics.Frontiers in neuroscience · 2023Review
- Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine.Advanced materials (Deerfield Beach, Fla.) · 2022Review
- A flexible neural implant with ultrathin substrate for low-invasive brain-computer interface applications.Microsystems & nanoengineering · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Chronically implanted neural probes are powerful tools to decode brain activity however, recording population and spiking activity over long periods remains a major challenge. Here, we designed and fabricated flexible intracortical Michigan-style arrays with a shank cross-section per electrode of 250 μm[Formula: see text] utilizing the polymer paryleneC with the goal to improve the immune acceptance. As flexible neural probes are unable to penetrate the brain due to the low buckling force threshold, a tissue-friendly insertion system was developed by reducing the effective shank length. The insertion strategy enabled the implantation of the four, bare, flexible shanks up to 2 mm into the mouse brain without increasing the implantation footprint and therefore, minimizing the acute trauma. In acute recordings from the mouse somatosensory cortex and the olfactory bulb, we demonstrated that the flexible probes were able to simultaneously detect local field potentials as well as single and multi-unit activity. Additionally, the flexible arrays outperformed stiff probes with respect to yield of single unit activity. Following the successful in vivo validation, we further improved the microfabrication towards a double-metal-layer process, and were able to double the number of electrodes per shank by keeping the shank width resulting in a cross-section per electrode of 118 μm[Formula: see text].