Evidence map›Paper›PMID 34553501›Full record

ArticlePhysiological reports2021

Transfer-function-free technique for the noninvasive determination of the human arterial pressure waveform.

Alessandro Giudici, Carlo Palombo, Carmela Morizzo, Michaela Kozakova, J Kennedy Cruickshank, Ian B Wilkinson, Ashraf W Khir

Open access · goldAbstract read
In one paragraph

Article in Physiological reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Alessandro GiudiciDepartment of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge, UK.ORCID 0000-0002-8288-3980
Carlo PalomboDepartment of Surgical, Medical, Molecular Pathology and Critical Area Medicine, University of Pisa, Pisa, Tuscany, Italy.
Carmela MorizzoDepartment of Surgical, Medical, Molecular Pathology and Critical Area Medicine, University of Pisa, Pisa, Tuscany, Italy.
Michaela KozakovaDepartment of Clinical and Experimental Medicine, University of Pisa, Pisa, Tuscany, Italy.
J Kennedy CruickshankSchool of Life-Course/Nutritional Sciences, King's College, St. Thomas' & Guy's Hospitals, London, Middlesex, UK.
Ian B WilkinsonDivision of Experimental Medicine and Immunotherapeutics, University of Cambridge, Cambridge, Cambridgeshire, UK.
Ashraf W KhirDepartment of Mechanical and Aerospace Engineering, Brunel University London, Uxbridge, UK.ORCID 0000-0002-0845-2891
University of Pisa · ITBrunel University of London · GBGuy's Hospital · GBUniversity of Cambridge · GB

Funding

British Heart Foundation FS/12/8/29377Department of Health
6 · The paper itself

Abstract

The estimation of central aortic blood pressure is a cardinal measurement, carrying effective physiological, and prognostic data beyond routine peripheral blood pressure. Transfer function-based devices effectively estimate aortic systolic and diastolic blood pressure from peripheral pressure waveforms, but the reconstructed pressure waveform seems to preserve features of the peripheral waveform. We sought to develop a new method for converting the local diameter distension waveform into a pressure waveform, through an exponential function whose parameters depend on the local wave speed. The proposed method was then tested at the common carotid artery. Diameter and blood velocity waveforms were acquired via ultrasound at the right common carotid artery while simultaneously recording pressure at the left common carotid artery via tonometer in 203 people (122 men, 50 ± 18 years). The wave speed was noninvasively estimated via the lnDU-loop method and then used to define the exponential function to convert the diameter into pressure. Noninvasive systolic and mean pressures estimated by the new technique were 3.8 ± 21.8 (p = 0.015) and 2.3 ± 9.6 mmHg (p = 0.011) higher than those obtained using tonometery. However, differences were much reduced and not significant in people >35 years (0.6 ± 18.7 and 0.8 ± 8.3 mmHg, respectively). This proof of concept study demonstrated that local wave speed, estimated from noninvasive local measurement of diameter and flow velocity, can be used to determine an exponential function that describes the relationship between local pressure and diameter. This pressure-diameter function can then be used for the noninvasive estimation of local arterial pressure.

Indexed as

Arterial PressureModels, CardiovascularAdolescentAdultAgedBlood Pressure DeterminationCarotid ArteriesCerebrovascular CirculationFemaleHumansMalecarotid arteryhypertensionlocal wave speednoninvasive estimation of pressurepressure

Identifiers

PMID34553501
PMCPMC8459031
OpenAlexW3200789405

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.